Rohrman Schweißtechnik XA-5001 Pro Скачать руководство пользователя страница 2

 Warning

Please read these instructions carefully before using the equipment!

Incorrect use can result in danger to life and health!

1. Introduction

Respiratory Systems is a combined face and breathing protection device for increased safety and comfort during welding.
Please read these instructions carefully before unpacking. For proper use, see User Instructions or contact your supplier for help. Adress and telephone 
number information is printed at the back of this leaflet.

Your Air Powered Respirator system should include:

a)

Autodim welding helmet top

b)

Autodim PAPR unit with attached battery

c)

Belt

d)

Autodim Battery charger

e)

Airflow indicator

f)

Instruction manual

g)

Backpack

If any of above components are not included in your kit, please contact the supplier immediately.

2. Approvals

The system complies with the requirements of European Standard EN 12941: 1998+A2_2008 as a THP device.
All components used in Respiratory System must be "Rohrman approved" manufacturers parts, and must be used in accordance with the instructions in this 
manual.

Notified Bidy: INSPEC International Limited 56 Leslie Hough Way, Salford, Greater Manchester, M6 6AJ United Kingdom (Notified body number 0194)

NOTE: The approval is not valid if the product is incorrectly used together with non-approved parts or components.

NOTE: Only the particle filter, gas filter and pre-filter can be used together with this system. Filters from other manufactures should under no circumstances 
be used.

3. Usage

The Respiratory System is designed to provide a supply of filtered air via a breathing tube to welding headpiece.
The complete system is a breathing device complying with EN 12941: 1998+A2:2008, class TH2 P R SL.
The equipment can be used in enviroment that requires a class TH2P breathing protection device. It protects against articulate contamination.

Limitations to use
The Respiratory System must only be used with the unit switched on. If the equipment is used without the unit switched on, there is a risk of high 
concentration of CO2 and the oxygen level in the head top will fall, thus little or no protection is given in the power-off state and this is considered to be an 
abnormal situation. Do not remove the head top or turn off the air filter unit until you have vacated the contaminated area.. If you are not sure about the 
concentration of pollution, or about equipment performance, ask the industrial safety engineer. The manufacturer or supplier is not responsible for injury 
following incorrect use or incorrect choice of equipment. 

DO NOT use the Autodim Welding helmet with the blower unit switched off.
DO NOT use the Autodim Welding helmet in an atmosphere that is immediately hazardous to user hygiene or health and or has oxygen content of less than 
19,5% or contains unknown substances.
DO NOT use the Autodim helmets in an explosive atmosphere.
DO NOT use Autodim helmets in confined spaces or areas of poor ventilation.
DO NOT use Autodim helmets in high winds.
DO NOT alter or modify in any way.
DO NOT touch any of the moving parts.
DO NOT allow water or other liquids to enter the impeller chamber, the filter or battery compartment.

Содержание XA-5001 Pro

Страница 1: ...Instruction manual Autodim Welding Helmet with ventilation unit ...

Страница 2: ... used 3 Usage The Respiratory System is designed to provide a supply of filtered air via a breathing tube to welding headpiece The complete system is a breathing device complying with EN 12941 1998 A2 2008 class TH2 P R SL The equipment can be used in enviroment that requires a class TH2P breathing protection device It protects against articulate contamination Limitations to use The Respiratory Sy...

Страница 3: ...n Click the above combination into the Turbo unit NOTE Make sure that the filter is properly placed into the casing while installing WARNING The filter can only be fitted to the turbo unit DO NOT directly fit the filter to the helmet hood Install the Autodim PAPR blower on the belt Remove the released buckle out of the belt FIGURE 3 A Draw the fasten belt out from the waist connector FIGURE 3 B Sl...

Страница 4: ...might make a loop and get caught up by something in the surrounding area Carefully observe the instructions that explain how the equipment is to be used before taking it into service All components must be installed used in accordance with this manual if the equipment is to offer the specified protection If any component is missing or if anything is not clear contact the supplier Marking on the ba...

Страница 5: ...d from damp and must ne used to charge non rechargeable batteries The battery will be full charged in about 3 5 hours also the heavy duty battery this depends on residual capacity The red light goes on during the battery is charged and the light will turn green when it is full charged FIGURE 7 The battery will discharge during a long period in storage For this reason always re charge the battery i...

Страница 6: ... low airflow alarm The airflow and alarm system must always be checked before using 1 Test air flow The system is equipped with an air flow indicator Connect the Airflow indicator to the breathing connector and press the ON button FIGURE 9 WARNING Do not use the system if the ball is bellow the mark line Check the filter and the battery and retest air flow 2 Test air flow alarm Remove the breathin...

Страница 7: ...e tightness so that it will be stable on the head The face seal should rest against your face with a comfortable pressure on your temples If the face seal doesn t make contact with you face you will not get sufficient sealing needed to offer the correct protection factor 6 LCD and Operation 6 1 LCD There is a LCD display on the Autordim PAPR unit to show the Autodim PAPR working condition Figure 1...

Страница 8: ...vel 3 is 230L min Autodim PAPR will shut down the entire circuit and switch to sleep mode if not used for more than 30 minutes Press the on button to can activate the system The Autodim PAPR must be operated in the temperature range of 5 C to 55 C and relative humidity less than 90 RH 7 PART LIST ...

Страница 9: ... 40 0A52001 Filter Cover Autodim PAPR 7 40 0A52002 Filter Autodim PAPR 8 40 0A52003 Prefilter Autodim PAPR 9 40 0A52004 Spark Arrestor Autodim PAPR 10 40 0A52005 Blower Unit Autodim PAPR 11 40 0A52006 Waist Belt and Dual Shoulder strap Autodim PAPR 12 40 0A52007 Backpag Autodim PAPR 13 40 0A52008 Breathin tube with cloth assembled Autodim PAPR 14 40 0A52009 LI ION Batteries Autodim PAPR 15 40 0A52...

Страница 10: ...h engages correctly 8 MAINTANCE STORAGE 8 1 Maintance The Autodim PAPR unit must be checked regulary and must be changed if it is damaged and cause leakage The filter must be changed if it is broken or it is blocked and does not give enough airflow The breathing tube must be changed if it is broken or has crevasse The battery must be charged when the low battery alarm rings Use a soft cloth to wip...

Страница 11: ...of protection P R indicates the filter type P Particle filter R Reusable type of particle filters and SL reflects the filter has been tested against particles of liquid and solid matter Warning sound indication Each grid stands for a period of 100ms Gray is the beep sound and blank grid is a quit period If several continued grids are in gray then there is a continous beep sound For example when th...

Страница 12: ...art found to be defective within this period Alternatively and at its discretion The company may replace This guarantee is subjekt to The Autodim PAPR unit has been used solely for the purpose for which it is intended The Autodim PAPR unit has not been subjekt to misuse accident modification or repair N B In the event of a claim contact the retailer from which the Autodim PAPR unit was purchased T...

Отзывы: