6.

 

Troubleshooting 

 

All Interrupt Issues 

-

 

Make sure the accelerometer is configured to issue interrupt signals in the way that your 
GPIO is programmed to handle them. 

-

 

An  oscilloscope  on  the  physical  interrupt  pin  can  be  a  valuable  tool  to  confirm  physical 
interrupt operation. 

-

 

Double  check  the  Tilt  Position  State  Mask  bits  in  Control  Register  2  (Tilt  Position 
Function),  the  axis  mask  bits  in  Interrupt  Control  Register  2  (Wake-up  Function),  and/or 
the Tap/Double-Tap Mask bits in Interrupt Control Register 3 (Tap/Double-Tap Function), 
and Free Fall Threshold value in Free Fall Threshold Register (Free Fall Detect Function) 

-

 

The Tilt Timer, WUF Timer, and TDT Timer(s) are based on their respective Output Data 
Rates, so  make  sure  the  correct cycle  time  is  used  when  calculating  the  expected  timer 
length (please refer to the specific product specification). 

 
Tilt Interrupt Not Working 

-

 

Make sure that the Tilt Position engine is enabled (TPE bit in Control Register 1). 

-

 

Try  shortening  the  timer  requirements  and  make  sure  the  next  state  transition  does  not 
occur until after the expiration of the Tilt Timer. 

-

 

Try increasing the Tilt Angle to ensure that the engine can see the transition between the 
X and Y axes and the Z axis (this should not be necessary if using the default value for Tilt 
Angle, but it’s worth considering if problems continue). 

 
WUF (Wake Up Function) and or BTS (Back-to-Sleep) Interrupts Are Not Working 

-

 

Make sure that the Wake-Up Function is enabled (WUFE bit in Control Register 4). 

-

 

Make sure that the Back-to-Sleep engine is enabled (BTSE bit in Control Register 4). 

-

 

If  Back-to-Sleep function is not  used (BTSE bit in Control Register 3 left at  0), the 

sleep

 

mode should be forced during the initial setup and after each Wake-up interrupt has fired 
through  setting  MAN_SLEEP  bit  to  1  in  Control  Register  5  (CNTL5).  This  will  also  clear 
WAKE bit in the STAT register to indicate the wake state is no longer valid. 

-

 

Make  sure  the  interrupt release  register INT_REL  is read to  clear  the  latched  interrupt  if 
was set previously, to clear WUFS and/or BTS bits in Interrupt Status 3 (INS3) registers. 

-

 

Try altering the threshold requirements to achieve desired operation. If the part is waking 
up too easily, try increasing the threshold. If the interrupt is not firing at all, the threshold 
may be set too high. 

-

 

Try shortening the timer requirements, and make sure the acceleration on an unmasked 
axis is above the threshold until the expiration of the WUF Timer.

 

 

 

 

TDT (Tap/Double-Tap) Interrupt Not Working 

-

 

Make sure that the TDT engine is enabled (TDTE bit in Control Register 1). 

-

 

Try  altering  the  threshold  requirements  to  achieve  desired  operation.  If  the  part  is 
generating  interrupts  too  often,  perhaps  due  to  a  large  noise  floor  created  by  excessive 
environmental vibrations, try increasing the performance index low threshold (TTL) and/or 
reducing  the  performance  index  high  threshold  (TTH).  If  the  interrupt  is  not  firing  at  all, 
perhaps the low threshold may be set too high, or the high threshold may be set too low. 

-

 

There  are  many  timers  in  this  engine  which  must  work  together  closely,  so  for  standard 
operation if one timer is changed the other timers may need to be changed proportionally.

 

 
 
 
 

Содержание Kionix KX132

Страница 1: ...ensure that our accelerometers will meet design expectations by default but it is not possible to provide default setting to work in every environment Depending on the intended application it is very...

Страница 2: ...pers refine their application requirements 3 1 Asynchronous Reading This example configures and enables the accelerometer to start outputting sensor data that can be asynchronously read from the outpu...

Страница 3: ...he latched interrupt will auto clear by default Register Name Address Value INC1 0x22 0x30 Write 0x10 to Interrupt Control 4 INC4 to set the Data Ready interrupt to be reported on physical interrupt p...

Страница 4: ...et the Output Data Rate ODR of the accelerometer to 50 Hz This step is optional as this is also a default setting Register Name Address Value ODCNTL 0x21 0x06 Write 0xE0 to Control 1 CNTL1 to set the...

Страница 5: ...Write 0x40 to Interrupt Control 4 INC4 to set the Buffer Full interrupt to be reported on physical interrupt pin INT1 Register Name Address Value INC4 0x25 0x40 Write 0xE0 to Buffer Control 2 BUF_CNTL...

Страница 6: ...er Name Address Value ODCNTL 0x21 0x06 Write 0x30 to Interrupt Control INC1 to enable physical interrupt pin INT1 set the polarity of the physical interrupt to active high and configure for latched op...

Страница 7: ...ta can be captured both before and after an event external trigger tap wakeup freefall Write 0x00 to Control 1 CNTL1 to set the accelerometer in stand by mode Register Name Address Value CNTL1 0x1B 0x...

Страница 8: ...set the output data rate for the back to sleep engine to its default of 0 781Hz Register Name Address Value CNTL4 0x1E 0x60 Write 0x01 to Control 5 CNTL5 to put the sensor into sleep mode MAN_SLEEP 1...

Страница 9: ...a which corresponds to 86 unique acceleration data samples The data set will include all the data prior to the trigger event plus all the data after the event 3 4 4 Buffer Reading Tips a The accelerat...

Страница 10: ...e high and configure for latched operation Register Name Address Value INC1 0x22 0x30 Write 0x02 to Interrupt Control 4 INC4 to set the Wakeup Function Interrupt WUFI1 1 to be reported on physical int...

Страница 11: ...ister Name Address Value WUFTH 0x49 0x80 BTSWUFTH 0x4A 0x00 Write 0xE0 to Control 1 CNTL1 to set the accelerometer into operating mode PC1 1 full power mode RES 1 data ready enabled DRDYE 1 range to 2...

Страница 12: ...WUFS bit in the Interrupt Status 3 INS3 Write 0x01 to Control 5 CNTL5 to force sleep state MAN_SLEEP 1 With Back to Sleep engine disabled this step is required in order to be able to detect additional...

Страница 13: ...ure for latched operation Register Name Address Value INC1 0x22 0x30 Write 0x0A to Interrupt Control 4 INC4 to set the Back to Sleep Interrupt BTSI 1 and Wakeup Interrupt WUFI1 to be reported on physi...

Страница 14: ...Wake up interrupt is triggered The following formula is used WUFC counts Desired Delay Time sec x OWUF Hz WUFC counts 0 1 sec x 50 Hz 5 counts Register Name Address Value WUFC 0x4D 0x05 Write 0x80 to...

Страница 15: ...A N A Continue to monitor the physical interrupt INT1 of the accelerometer if the lack of acceleration input profile satisfies the criteria previously established for the 0 5g of no motion detect thre...

Страница 16: ...register Here we assume an 80 msec timer will be sufficient Note that each count value written to this register is calculated as 1 Tilt Position ODR 1 12 5Hz 80 msec Register Name Address Value TILT_...

Страница 17: ...terrupt INT1 of the accelerometer If changes in the tilt position satisfies the criteria previously established then there should be a positive latched interrupt present Also the interrupt would be re...

Страница 18: ...e TDTRC 0x2A 0x03 Write 0x78 to Tap Double Tap Counter register TDTC to set the counter to 0 3 sec The TDTC counts starts at the beginning of the fist tap and it represents the minimum time separation...

Страница 19: ...otal amount of time that the two taps in a double tap event can be above the PI threshold TTL This step is optional as this is also a default setting This setting can be adjusted as needed Register Na...

Страница 20: ...function Register Name Address Value CNTL1 0x1B 0xC4 Monitor the physical interrupt INT1 of the accelerometer if the acceleration input profile satisfies the criteria previously established for Tap Do...

Страница 21: ...ts 0 0625 g count 0 5 g Register Name Address Value FFTH 0x32 0x08 Write 0x04 to Free Fall Counter Register FFC to set the Free fall delay detection to 0 320 sec Note that the period of the free fall...

Страница 22: ...atisfies the criteria previously established for the 0 5g free fall detect threshold level in both positive and negative directions of the X Y Z axis for more than 0 320 second then there should be a...

Страница 23: ...in Control Register 1 is asserted it takes from 2 ms to 1300 ms depending on the ODR and Power Mode setting before the acceleration outputs are valid See the relevant Product Specification for detail...

Страница 24: ...ister must be read in order to clear the physical interrupt pin This will also clear the Interrupt Source Registers and the INT bit 0x10 in the Status Register Microcontroller GPIO Interrupt Handling...

Страница 25: ...WUFE bit in Control Register 4 Make sure that the Back to Sleep engine is enabled BTSE bit in Control Register 4 If Back to Sleep function is not used BTSE bit in Control Register 3 left at 0 the sle...

Страница 26: ...nt effect on tap double tap direction resolution If tap detection is desired the part should be placed as far away from the edges of the device housing as possible with the ideal location being at the...

Страница 27: ...ing Automatic sleep mode Step counting pedometer 9 Theory of Operation Kionix MEMS linear tri axis accelerometers function on the principle of differential capacitance Acceleration causes displacement...

Отзывы: