37/46
Application Note
BD71837MWV Platform Design Guide
© 2018 ROHM Co., Ltd.
No. 61AN002E Rev.001
May.2018
5.3.8.3. Layout Example
About the parts placement for each capacitor around BUCK8, the below reference layout can be referred to.
BUCK8_FB should be connected to near output capacitors.
Figure 5.22
BUCK8 Layout Example (Top Layer)
Output Cap
BUCK8_VIN
BUCK8_LX
Input
Cap
Feedback
point
Inductor