Rohl GKIT1655 Скачать руководство пользователя страница 19

www.rohlhome.com

Consult your local ROHL showroom for additional information and specifications. For complete warranty details and a list of showrooms, go to www.rohlhome.com.

INSTALLATION INSTRUCTIONS

Issue 

®

1

• CARTRIDGE REPLACMENT

The filter cartridge in your instant hot tap system needs to be changed every six months in order to

ensure the system works at its optimum performance.

Changing the filter cartridge is a simple matter:

1. Switch off the heater tank either at the mains or by pressing

    the centre button on the heater tank touch screen.

    ***Important Notice*** – run off all hot water until
    just cold water is coming out of the tap.

2. Place a small bowl under the filter housing sump to catch the
    small amount of water that will be released when removing the

    filter housing sump.

3. Turn the filter housing sump anti-clockwise a quarter turn, to

    allow the filter housing sump to drop down from the filter
housing head.

4. Once the sump is removed, unscrew the filter housing cap

    from the sump and tip any water out of the sump into the bowl
    or sink.

5. Remove the old filter by pulling the filter from the cap.

6. Dispose of the old filter in the normal household waste bin.

Remebering to keep the filter insert as you will need

    this for the replacement filter.

7. Fit the new filter by pushing the filter insert into the top of
    the filter then into the cap; you may need to wet the ‘O’ seals in

    the top of

    the filter as shown in the attached drawing referenced A.
    Always inspect the 'O' seals for damage; for replacements use
    contact details below.

8. Screw the sump back onto the cap (Ensuring that the ‘O’ seal
    is in place), referenced B.

9. Push the filter housing sump back into the filter housing head

    and turn clockwise until it stops.

Important Notice

The filter is now ready to use – it is vitally important that you

follow the process below to ensure that all air is bled from the
system.

Place a jug under the spout as water will splutter

from the spout until all of the air is expelled

.

Operate the instant hot tap lever to dispense water, run-off at

least 0.35 gallons of water, let the system rest for at least 30

seconds and run another 0.35 gallons of water, repeat this at
least one more time – your instant hot water tap should now be

ready for use.

You must now thoroughly check the unit for any water
leaks and take this opportunity to check for any excess
wear or damage to the system. If there are no leaks

please continue:

10. Now switch the heater tank back on at the mains, or by

     pressing the button in the centre of the heater tank touch
     screen.

11. Set the desired temperature by pressing the right hand

     button until the desired temperature is displayed (usually 98

     degrees)

12. Press the left hand button to confirm the temperature

setting.

13. The heater tank will now heat up to the desired temperature

      and once completed the system is ready for use.

FILTER

HOUSING

SUMP

FILTER

HOUSING

CAP

FILTER

MOUNT

BRACKET

FILTER

HOUSING

HEAD

FILTER

INSERT

FILTER

'O' SEAL

(B)

'O' SEALS 

(A)

'O' SEALS 

(A)

Should you require any advice, or a quick solution to a problem with this product please

contact in the first instance the supplier/showroom from which it was purchased.

• T: 1-800-777-9762 • E: [email protected] • W: www.rohlhome.com

• Instant Hot Tap

9001914U

Содержание GKIT1655

Страница 1: ...llowing items U 1998 Hot water tank G1655LM 2 Hot water faucet U 1106 Hot water filter Instantly provides near boiling filtered water for beverages and food preparation Unique Anti Scald lock innovati...

Страница 2: ...www rohlhome com Consult your local ROHL showroom for additional information and specifications For complete warranty details and a list of showrooms go to www rohlhome com INSTALLATION INSTRUCTIONS...

Страница 3: ...R DISPENSER COLLECTION FOR USE ONLY WITH PERRIN AND ROWE HOT WATER TANK SCALDING HAZARD The tap dispenses water up to 208 4 F 98 C which can instantly cause scalds or burns Use care when operating thi...

Страница 4: ...n manual that accompanies your Perrin and Rowe heater tank unit To avoid perminent damage to the heater tank it is important not to plug the unit until indicated in heater tank installation manual Onl...

Страница 5: ...NOTICE AN ASSISTANT MAY BE NEEDED TO HOLD THE TAP IN PLACE WHILE SECURING TO EASE FEEDING OF THE TUBES THROUGH THE HOLE FIRST INSERT THE BLUE TUBE WITH QUICK CONNECT ATTACHMENT AND THEN INSERT THE RE...

Страница 6: ...Parker Irvine California 92618 1605 Ph 800 777 9762 Fax 714 557 8635 We would like to thank you for purchasing a ROHL product and take this opportunity to invite you to look at other luxury products...

Страница 7: ...e warranty details and a list of showrooms go to www rohlhome com INSTALLATION INSTRUCTIONS Electronic Instant Hot Water Appliance Installation Operation and Care Instructions Please read these instru...

Страница 8: ...ot water appliance This electronic instant hot water appliance is not intended for commercial use IMPORTANT NOTICE This product can cause harm if installed incorrectly and should only be installed by...

Страница 9: ...injury The safety information will tell you what the potential danger is how to avoid it and identify what will happen if you do not operate following the instruction Electric Shock Using an ungrounde...

Страница 10: ...Domestic use only The electronic instant hot water appliance must be installed vertically as shown on front cover with inlet and outlet connections at the top of appliance Ensure the front of the unit...

Страница 11: ...be blocked and will void the guarantee Environment requirement Don t install the electronic instant hot water appliance outdoors or in a location that may fall below 32F otherwise the pipes and the Di...

Страница 12: ...hot water Dis penser or close to it to ensure the connection pipes will connect from the instant hot wa ter Dispenser to the electronic instant hot water appliance The electronic instant hot water ap...

Страница 13: ...nd move to check the complete installation for leaks Step 3 Priming and Checking for Water Tightness Before the electronic instant hot water appliance is plugged into the power socket it must be teste...

Страница 14: ...onic Control Display Panel ON OFF to control the power it will also control the display ON OFF Confirmation and heating control switch Temperature setting 7 temperature settings 208 F max 206 F 203 F...

Страница 15: ...to freezing tempera tures If there is a possibility of this the system must be drained of water Shut off the mains supply and unplug the unit from the electricity mains and allow the tank to cool for...

Страница 16: ...let Make sure that the circuit breaker and fuse are working correctly Turn on the power and touch the on off button and then set the required temperature and confirm the heat up Water is too hot Water...

Страница 17: ...ight away The electronic instant hot water appliance is design for non pressurised oper ation and there will be slight delay till the near boiling water appears After a large volume of water has been...

Страница 18: ...nty details and a list of showrooms go to www rohlhome com INSTALLATION INSTRUCTIONS Customer Services ROHL LLC 3 Parker Irvine California 92618 1605 Phone 800 777 9762 www rohlhome com Guarantee Void...

Страница 19: ...ontact details below 8 Screw the sump back onto the cap Ensuring that the O seal is in place referenced B 9 Push the filter housing sump back into the filter housing head and turn clockwise until it s...

Страница 20: ...he tap to the threaded side of the filter housing Attach the threaded end of the push fit braided hose to the top of the heater tank as shown below Re fit the Filter Sump to the Mounting Bracket Pleas...

Отзывы: