INSTALLATION INSTRUCTIONS

INSTALLATION  CONTINUED 

Step 2 – Connect Dispenser  

The electronic instant hot water appliance inlet connection is a 3/8” BSP male threaded 
connector. The outlet connector is a 3/8” BSP male thread connector. 

Check the connections type and size on the instant hot water Dispenser for the inlet and 
outlet connections. 

Screw on the inlet and outlet pipe the correct connectors and tighten with a wrench. 

Connect the cold and hot Dispenser inlet hoses to the mains in the normal way. Fitting a 
pressure reducing valve to the cold mains inlet if the mains pressure is above 5bar. Tighten 
with a wrench and move to check the complete installation for leaks.  

 

 

 

Step 3 – Priming and Checking for Water Tightness 

Before the electronic instant hot water appliance is plugged into the power socket it must 
be tested for water tightness and no leaks. 
Open all water valves to allow water to flow to the instant hot water Dispenser.  
Turn the spring back instant hot water handle and hold to fill the electronic instant hot 

water appliance this will take about 90 seconds.  

When the electronic instant hot water appliance is full, water will flow from 
the instant hot water Dispenser spout.  Initially as air is purged the out let 

may spit or splutter. To remove air from the system continue to operate the lever for 1-2 
gallons or more if needed. Turn the instant hot water handle off and check all connections 
for water tightness and leaks. 

Any leaking joint must be tightened to ensure no water leakage and the above priming 
undertaken again and checked for water tightness  before connecting to the power socket. 

 

Содержание GKIT1655

Страница 1: ...llowing items U 1998 Hot water tank G1655LM 2 Hot water faucet U 1106 Hot water filter Instantly provides near boiling filtered water for beverages and food preparation Unique Anti Scald lock innovati...

Страница 2: ...www rohlhome com Consult your local ROHL showroom for additional information and specifications For complete warranty details and a list of showrooms go to www rohlhome com INSTALLATION INSTRUCTIONS...

Страница 3: ...R DISPENSER COLLECTION FOR USE ONLY WITH PERRIN AND ROWE HOT WATER TANK SCALDING HAZARD The tap dispenses water up to 208 4 F 98 C which can instantly cause scalds or burns Use care when operating thi...

Страница 4: ...n manual that accompanies your Perrin and Rowe heater tank unit To avoid perminent damage to the heater tank it is important not to plug the unit until indicated in heater tank installation manual Onl...

Страница 5: ...NOTICE AN ASSISTANT MAY BE NEEDED TO HOLD THE TAP IN PLACE WHILE SECURING TO EASE FEEDING OF THE TUBES THROUGH THE HOLE FIRST INSERT THE BLUE TUBE WITH QUICK CONNECT ATTACHMENT AND THEN INSERT THE RE...

Страница 6: ...Parker Irvine California 92618 1605 Ph 800 777 9762 Fax 714 557 8635 We would like to thank you for purchasing a ROHL product and take this opportunity to invite you to look at other luxury products...

Страница 7: ...e warranty details and a list of showrooms go to www rohlhome com INSTALLATION INSTRUCTIONS Electronic Instant Hot Water Appliance Installation Operation and Care Instructions Please read these instru...

Страница 8: ...ot water appliance This electronic instant hot water appliance is not intended for commercial use IMPORTANT NOTICE This product can cause harm if installed incorrectly and should only be installed by...

Страница 9: ...injury The safety information will tell you what the potential danger is how to avoid it and identify what will happen if you do not operate following the instruction Electric Shock Using an ungrounde...

Страница 10: ...Domestic use only The electronic instant hot water appliance must be installed vertically as shown on front cover with inlet and outlet connections at the top of appliance Ensure the front of the unit...

Страница 11: ...be blocked and will void the guarantee Environment requirement Don t install the electronic instant hot water appliance outdoors or in a location that may fall below 32F otherwise the pipes and the Di...

Страница 12: ...hot water Dis penser or close to it to ensure the connection pipes will connect from the instant hot wa ter Dispenser to the electronic instant hot water appliance The electronic instant hot water ap...

Страница 13: ...nd move to check the complete installation for leaks Step 3 Priming and Checking for Water Tightness Before the electronic instant hot water appliance is plugged into the power socket it must be teste...

Страница 14: ...onic Control Display Panel ON OFF to control the power it will also control the display ON OFF Confirmation and heating control switch Temperature setting 7 temperature settings 208 F max 206 F 203 F...

Страница 15: ...to freezing tempera tures If there is a possibility of this the system must be drained of water Shut off the mains supply and unplug the unit from the electricity mains and allow the tank to cool for...

Страница 16: ...let Make sure that the circuit breaker and fuse are working correctly Turn on the power and touch the on off button and then set the required temperature and confirm the heat up Water is too hot Water...

Страница 17: ...ight away The electronic instant hot water appliance is design for non pressurised oper ation and there will be slight delay till the near boiling water appears After a large volume of water has been...

Страница 18: ...nty details and a list of showrooms go to www rohlhome com INSTALLATION INSTRUCTIONS Customer Services ROHL LLC 3 Parker Irvine California 92618 1605 Phone 800 777 9762 www rohlhome com Guarantee Void...

Страница 19: ...ontact details below 8 Screw the sump back onto the cap Ensuring that the O seal is in place referenced B 9 Push the filter housing sump back into the filter housing head and turn clockwise until it s...

Страница 20: ...he tap to the threaded side of the filter housing Attach the threaded end of the push fit braided hose to the top of the heater tank as shown below Re fit the Filter Sump to the Mounting Bracket Pleas...

Отзывы: