VOR/ILS Analyzer EVS200
0796.1800.02
E-8
31
Chapter 3: Operation
Unit related control commands
Command RF (frequency in kHz)
command
function
RF (frequency in kHz) <frequency information> setting or scanning receiving frequency
With the command RF (frequency in kHz) a frequency input is possible in the ranges of 107000 to
119000 kHz and 319000 to 341000 kHz. With this command it is also possible to scan the tuned
frequency when the command RF is transmitted to the EVS200 without additionally parameters. The
unit responses with the frequency information.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
input:
RF107000 <CR>
rf107000 <CR>
READY <CR/LF>
READY <CR/LF>
query:
RF<CR>
rf<CR>
107000kHz <CR/LF>
107000kHz <CR/LF>
Command LO
command
function
LO
<Local>
set unit local mode
Because local operation is automatically locked when the unit is controlled by a controller, the com-
mand LO (local) performs further local operation at the unit.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
input:
LO<CR>
lo<CR>
READY <CR/LF>
READY <CR/LF>
Command EC0
command
function
EC0
<echo off >
selection of communication
EVS200 does not retransmit the received control string.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
query:
EC0 <CR>
ec0 <CR>
READY <CR/LF>
READY <CR/LF>
Содержание VOR/ILS Analyzer EVS200
Страница 1: ...0798 1988 12 08 User Manual VOR ILS Analyzer EVS200 0796 1800 02 ...
Страница 4: ......
Страница 24: ...VOR ILS Analyzer EVS200 0796 1800 02 E 8 15 Chapter 3 Operation Operating instructions of SETUP Mode ...
Страница 25: ...VOR ILS Analyzer EVS200 0796 1800 02 E 8 16 Chapter 3 Operation ILS Mode Operating instructions of ILS Mode ...
Страница 26: ...VOR ILS Analyzer EVS200 0796 1800 02 E 8 17 Chapter 3 Operation Operating instructions of Y t setup menu ...
Страница 27: ...VOR ILS Analyzer EVS200 0796 1800 02 E 8 18 Chapter 3 Operation Operating instructions of STORE DDM menu ...
Страница 28: ...VOR ILS Analyzer EVS200 0796 1800 02 E 8 19 Chapter 3 Operation ...
Страница 30: ...VOR ILS Analyzer EVS200 0796 1800 02 E 8 21 Chapter 3 Operation VOR Mode Operating instructions of VOR Mode ...
Страница 36: ...VOR ILS Analyzer EVS200 0796 1800 02 E 8 27 Chapter 3 Operation ...