background image

1171.0000.42 - 07 

Page 1 

Basic Safety Instructions 

Always read through and comply with the following safety instructions! 

All plants and locations of the Rohde & Schwarz group of companies make every effort to keep the safety 
standards of our products up to date and to offer our customers the highest possible degree of safety. Our 
products and the auxiliary equipment they require are designed, built and tested in accordance with the 
safety standards that apply in each case. Compliance with these standards is continuously monitored by 
our quality assurance system. The product described here has been designed, built and tested in 
accordance with the EC Certificate of Conformity and has left the manufacturer’s plant in a condition fully 
complying with safety standards. To maintain this condition and to ensure safe operation, you must 
observe all instructions and warnings provided in this manual. If you have any questions regarding these 
safety instructions, the Rohde & Schwarz group of companies will be happy to answer them.

 

Furthermore, it is your responsibility to use the product in an appropriate manner. This product is designed 
for use solely in industrial and laboratory environments or, if expressly permitted, also in the field and must 
not be used in any way that may cause personal injury or property damage. You are responsible if the 
product is used for any purpose other than its designated purpose or in disregard of the manufacturer's 
instructions. The manufacturer shall assume no responsibility for such use of the product.  

The product is used for its designated purpose if it is used in accordance with its product documentation 
and within its performance limits (see data sheet, documentation, the following safety instructions). Using 
the product requires technical skills and, in some cases, a basic knowledge of English. It is therefore 
essential that only skilled and specialized staff or thoroughly trained personnel with the required skills be 
allowed to use the product. If personal safety gear is required for using Rohde & Schwarz products, this 
will be indicated at the appropriate place in the product documentation. Keep the basic safety instructions 
and the product documentation in a safe place and pass them on to the subsequent users. 

Observing the safety instructions will help prevent personal injury or damage of any kind caused by 
dangerous situations. Therefore, carefully read through and adhere to the following safety instructions 
before and when using the product. It is also absolutely essential to observe the additional safety 
instructions on personal safety, for example, that appear in relevant parts of the product documentation. In 
these safety instructions, the word "product" refers to all merchandise sold and distributed by the Rohde & 
Schwarz group of companies, including instruments, systems and all accessories. For product-specific 
information, see the data sheet and the product documentation. 

Safety labels on products 

The following safety labels are used on products to warn against risks and dangers. 

Symbol 

Meaning 

Symbol 

Meaning 

Notice, general danger location 

Observe product documentation 

ON/OFF supply voltage 

Caution when handling heavy equipment 

Standby indication 

Danger of electric shock 

Direct current (DC) 

Содержание TSME-Z3

Страница 1: ...R S TSME Z3 Backpack System for TSME Drive Test Scanner Getting Started Getting Started C9 2 1519 0994 02 02 Test Measurement...

Страница 2: ...s not binding R S is a registered trademark of Rohde Schwarz GmbH Co KG CDMA2000 is a registered trademark of the Telecommunications Industry Association TIA USA WiMAX Forum is a registered trademark...

Страница 3: ...the product The product is used for its designated purpose if it is used in accordance with its product documentation and within its performance limits see data sheet documentation the following safe...

Страница 4: ...dangers Indicates a hazardous situation which if not avoided will result in death or serious injury Indicates a hazardous situation which if not avoided could result in death or serious injury Indicat...

Страница 5: ...ot observed either at all or to the extent necessary electric shock fire and or serious personal injury or death may occur 1 Prior to switching on the product always ensure that the nominal voltage se...

Страница 6: ...be fuse protected in such a way that anyone who has access to the product as well as the product itself is adequately protected from injury or damage 14 Use suitable overvoltage protection to ensure...

Страница 7: ...masks and protective clothing must be worn 7 Laser products are given warning labels that are standardized according to their laser class Lasers can cause biological harm due to the properties of the...

Страница 8: ...n permitted 5 If a cell develops a leak the fluid must not be allowed to come into contact with the skin or eyes If contact occurs wash the affected area with plenty of water and seek medical aid 6 Im...

Страница 9: ...s substances or fuels can cause health problems and lead to environmental damage For additional information about environmental protection visit the Rohde Schwarz website Instrucciones de seguridad el...

Страница 10: ...el uso del producto Deber n tenerse en cuenta todas las dem s informaciones de seguridad como p ej las referentes a la protecci n de personas que encontrar n en el cap tulo correspondiente de la docu...

Страница 11: ...l producto se emplea de forma sin nima el t rmino CUIDADO Las palabras de se al corresponden a la definici n habitual para aplicaciones civiles en el rea econ mica europea Pueden existir definiciones...

Страница 12: ...la tensi n preseleccionada en el producto coincida con la de la red de alimentaci n el ctrica Si es necesario modificar el ajuste de tensi n tambi n se deber n cambiar en caso dado los fusibles corre...

Страница 13: ...efectuadas por un electricista especializado 13 En el caso de dispositivos fijos que no est n provistos de fusibles interruptor autom tico ni otros mecanismos de seguridad similares el circuito de ali...

Страница 14: ...empresario operador tiene la obligaci n de evaluar y se alizar las reas de trabajo en las que exista un riesgo elevado de exposici n a radiaciones 6 Tenga en cuenta que en caso de incendio pueden desp...

Страница 15: ...r ni fuego Debe evitarse el almacenamiento a la luz directa del sol Las celdas y bater as deben mantenerse limpias y secas Limpiar las conexiones sucias con un pa o seco y limpio 3 Las celdas o bater...

Страница 16: ...vos el ctricos usados no se deben desechar con los residuos dom sticos sin clasificar sino que deben ser recogidos por separado Rohde Schwarz GmbH Co KG ha elaborado un concepto de eliminaci n de resi...

Страница 17: ...ed for exam ple according to the ISO9001 and ISO14001 management systems Environmental commitment Energy efficient products Continuous improvement in environmental sustainability ISO14001 certified en...

Страница 18: ...ument up to date and to be informed about new application notes related to your instrument please send an e mail to the Customer Support Center stating your instrument and your wish We will take care...

Страница 19: ...Z3 backpack provides such a solution which allows for indoor measurements of coverage and interfer ence in GSM WCDMA LTE CDMA2000 EVDO TD SCDMA WiMAX and TETRA networks In addition to scanner measure...

Страница 20: ...ner and Mobile Device Configuration on page 8 Framework to mount up to two optional recharcheable batteries acces sory see chapter 2 3 Power Supply on page 6 Gigabit Ethernet switch 4 DL ports for R S...

Страница 21: ...lead through the side wall for external operation Fig 2 1 Fully equipped R S TSME Z3 backpack 2 2 System Unit The system unit contains the following connectors and interface elements Fig 2 2 System un...

Страница 22: ...nal DC power source typically a car bat tery No batteries are required inside the backpack A DC power supply cable with a cigarette lighter plug is provided with the R S TSME Z3 The external DC power...

Страница 23: ...t external DC power source to provide an interruption free power supply If both external and battery power supplies are available the external power source is used by default Risks of rechargeable bat...

Страница 24: ...one position one TSME Z3M1 mounting kit for one mobile device is required The following configurations are possible Table 2 1 Possible R S TSME Z3 configurations Number of R S TSMEs Max number of mobi...

Страница 25: ...gured in the factory according to the user s specifications at an extra charge Please contact your local Rohde Schwarz sales office Connectors for R S TSME Ethernet switch The gigabit Ethernet switch...

Страница 26: ...ackpack Ensure that all fan openings on both sides of the backpack are unobstructed and the airflow perforations are unimpeded Setting up the System 10 Completing the Pre Configured Measurement System...

Страница 27: ...late of the R S TSME mounting set to the bottom of the upper R S TSME b Lay the upper R S TSME on the lower R S TSME so that the connectors of both devices are on the same side Using 2 screws on each...

Страница 28: ...ng the front of the R S TSME 3 Insert the base metal plate with the attached R S TSME s in the mounting rail of the system unit so that the connectors of the R S TSME s are on the same side as the cor...

Страница 29: ...onnect each R S TSME to the system unit using a LAN cable and a power supply cable which is provided with the mounting set Fig 3 1 R S TSME Z3 cable connections 7 Connect the control PC for the R S TS...

Страница 30: ...de panel of the R S TSME using two screws Fasten one screw in the fourth hole from the left and the other screw in the fourth hole from the right on the R S TSME To fasten the GPS antenna A velcro str...

Страница 31: ...igure 3 2 2 Fasten the other side of the velcro strip to the bottom of the GPS antenna 3 Attach the GPS antenna to the velcro strip on the base unit Make sure the antenna cable for the GPS module face...

Страница 32: ...ipment to complete the measurement setup for scanning or testing mobile devices To complete the measurement system 1 For scanning a Using a LAN cable connect the control PC for the R S TSME s to the H...

Страница 33: ...l DC power supply Connect the DC power supply cable to the DC IN connector on the system unit and the cigarette lighter plug to the external DC power supply To provide power from rechargeable batterie...

Страница 34: ...r a low battery charge are indicated by LED signals an acoustic signal or both The fol lowing sections provide information on the possible causes for these warnings and some recommendations how to sol...

Страница 35: ...ff No power supplied to the sys tem Connect external power supply or battery and switch on system unit see To switch the system unit on on page 17 Green Unit is supplied with power Yellow Standby due...

Страница 36: ...unobstructed Check the connectors of the built in cooling fans to the system unit and make sure they are work ing Open the backpack and let the system cool off 4 2 Acoustic Signals The system unit pro...

Отзывы: