Setting up
R&S
®
TS-PSM5
28
User Manual 1178.2809.02 ─ 01
●
Removing the corresponding front plate section on the CompactTSVP housing by
undoing the screws.
●
Inserting the R&S TS-PSM5 with moderate pressure.
●
The top pilot pin of the R&S TS-PSM5 must be guided into the right-hand hole, the
bottom one into the left-hand hole on the CompactTSVP housing.
●
The R&S TS-PSM5 is correctly inserted if a definite stop can be felt.
●
Tighten the screws on the top and bottom of the front plate of theR&S TS-PSM5.
Damaged backplane due to bent pins
Bent pins may result in permanent damage to the backplane.
Check the backplane connector for bent pins!
Any pins that are bent must be straightened!
When module is connected, it must be guided with both hands and carefully pressed
into the backplane connector.
6.2.2 Installation of the R&S TS-PSM5 in the PowerTSVP R&S TS-PWA3
Slots 1\2 to 15\16 are permitted for installation in the R&S TS-PWA3 PowerTSVP . The
voltage supply for the R&S TS-PSM5 is guaranteed on all slots in the R&S TS-PWA3
PowerTSVP even without a R&S TS-PRIO module attached to the rear. Optionally the
R&S TS-PRIO5 module can be placed in rear slots 1\2 to 13\14. With this module all 2
A and all 50 A channels can be made accessible on the rear of the R&S TS-PWA3
PowerTSVP. If the R&S TS-PSM5 is operated in slots 15\16, there is the capability for
both R&S TS-PWA3 PowerTSVP and R&S TS-PCA3 CompactTSVP to run all 2 A
channels and the 50 A channels 5 and 8 to the X3 and X4 connectors on the rear of
the chassis via the optional R&S TS-PK04 cable set.
Installation in slots 1\2 must be carried out with the utmost care, as components on the
underneath of the R&S TS-PSM5 can be damaged via contact with the adjacent power
supply unit. It must be ensured that after the installation there are no points of contact
between the HF seal of the power supply unit, which may be warped, and the R&S TS-
PSM5 . For safety reasons it is recommended that slots 1\2 in the R&S TS-PWA3
PowerTSVP may not be used for the R&S TS-PSM5.
To install plug-in module High-Power Switch Module R&S TS-PSM5, proceed as fol-
lows:
●
Shut down and switch off the R&S TS-PWA3 PowerTSVP.
●
Select an appropriate front slot. The R&S TS-PSM5 requires two slots.
See also 'PowerTSVP operating manual', 'Permissible module configurations' sec-
tion.
Installation of the R&S TS-PSM5