2. Use the built-in
function to display the physical location of the
selected connector.
A blinking LED on the rear panel indicates the selected connector, too.
Show Connector
Accesses a dialog that displays the physical location of the selected connector on the
front/rear panel of the instrument.
A blinking LED on the front/rear panel indicates the selected connector, too (see
ter 11.2.2.4, "Status indicators"
T/M/(C) Connector Direction
Determines whether the connector is used as an input or an output.
Remote command:
[:SOURce<hw>]:INPut:TM<ch>:DIRection
Signal
Determines the control signal that is input or output at the selected connector. Whether
the connector is used as an input or an output is selected by the parameter
.
Refer to
for an overview of the available control signals.
"Data"
Input for external serial data signal
"Baseband A Marker 1"
A broad selection of suitable marker signals is offered in the "Marker"
tab of the corresponding digital standard.
"Symbol Clock A"
Output of the internal clock signal used for digital modulations. The
signal is generated automatically when the standard is switched on.
"Feedback"
Input for local feedback signal, required for 3GPP HSUPA HARQ
Feedback, 3GPP Dynamic Power Control or EUTRA/LTE Closed
Loop BS tests.
Remote command:
[:SOURce<hw>]:INPut:TM<ch>:SIGNal
Threshold Clock/Trigger Input
Sets the high/low threshold in volts for the trigger and clock signal inputs of the base-
band section.
Remote command:
[:SOURce<hw>]:INPut:TM:CLOCk:LEVel
[:SOURce<hw>]:INPut:TM:TRIGger:LEVel
Impedance Clock/Trigger Input
Selects the input impedance for the external trigger/clock inputs.