The fader setting selects an SUA partition. The numbering is reversed, so that the low-
est fader number selects the highest SUA partition. This reverse numbering allows you
to select the same number for the fader and the baseband unit, because they address
different SUA partitions.
Example: Baseband unit "2.SUA4" selects SUA partition 4 in CMW 2. Fader "2.Fader4"
selects SUA partition 1 in CMW 2. So they can be combined.
The fader selection offers only values compatible with the baseband setting. If there is
only one possible value, the selection is grayed out, displaying this value.
Remote command:
ROUTe:NIOT:SIGN<i>:SCENario:SCFading[:FLEXible]:INTernal
ROUTe:NIOT:SIGN<i>:SCENario:TROFading[:FLEXible]:INTernal
Base Band Unit
Selects the signaling unit to be used. This setting is especially useful for multi-CMW
setups, to control which instrument is used.
Remote command:
ROUTe:NIOT:SIGN<i>:SCENario[:FLEXible]:SCELl
ROUTe:NIOT:SIGN<i>:SCENario:SCFading[:FLEXible]:INTernal
ROUTe:NIOT:SIGN<i>:SCENario:TROFading[:FLEXible]:INTernal
2.3.5
RF Settings
Access: "Config" hotkey > "RF Settings" section.
The parameters in this section configure the RF input and output paths.
Figure 2-21: RF settings
For descriptions of the parameters, refer to the subsections.
...........................................................................................49
2.3.5.1
RF Signal Routing
Access: "Config" hotkey > "RF Settings" > "RF Output (TX)" and "RF Input (RX)" sec-
tions.
This section configures the RF input path and the RF output path.