background image

Putting into Operation

R&S

®

NGP800

10

Getting Started 5601.5603.02 ─ 05

Risk of instrument damage during operation

An unsuitable operating site or test setup can cause damage to the instru-
ment and the connected devices. Ensure the following operating conditions
before you switch on the instrument:

The instrument is dry and shows no sign of condensation

The instrument is positioned as described in 

Chapter 3.4.1, "Bench

Operation"

on page 15

The ambient temperature does not exceed the range specified in the
data sheet

Signal levels at the input connectors are all within the specified ranges

Signal outputs are correctly connected and not overloaded

EMI impact on measurement results

Electromagnetic interference (EMI) may affect the measurement results.
To suppress the generated EMI:

Use suitable shielded cables of high quality, for example, LAN cables

Note the EMC classification in the data sheet

3.1

 

Safety

This instrument was built in compliance with DIN EN 61010-1 (VDE 0411 part 1),
safety regulations for electrical instruments, control units and Iaboratory equip-
ment.

It has been tested and shipped from the plant in safe condition. It is also in com-
pliance with the regulations of the European standard EN 61010-1 and the inter-
national standard IEC 61010-1.

To maintain this condition and ensure safe operation, you must observe all
instructions and warnings given in this user manual. Casing, chassis and all mea-
suring ports are connected to a protective earth conductor. The instrument is
designed in compliance with the regulations of protection class I.

Safety

Содержание NGP800 Series

Страница 1: ...R S NGP800 Power Supply Series Getting Started Getting Started Version 05 5601560302 Æ1Æ32 ...

Страница 2: ... 20A 64V 10A Power Supply 800 W 5601 4007 04 2019 Rohde Schwarz GmbH Co KG Mühldorfstr 15 81671 München Germany Phone 49 89 41 29 0 Fax 49 89 41 29 12 164 Email info rohde schwarz com Internet www rohde schwarz com Subject to change Data without tolerance limits is not binding R S is a registered trademark of Rohde Schwarz GmbH Co KG Trade names are trademarks of the owners 5601 5603 02 Version 05...

Страница 3: ...sic Safety Instructions and the product documentation in a safe place and pass them on to the subsequent users Riesgo de lesiones y daños en el instrumento El instrumento se debe usar de manera adecuada para prevenir descargas eléctricas incendios lesiones o daños materiales No abrir la carcasa del instrumento Lea y cumpla las Instrucciones de seguridad elementales suministradas con el instrumento...

Страница 4: ...die Produktdokumentation gut auf und geben Sie diese an weitere Benutzer des Produkts weiter Risque de blessures et d endommagement de l appareil L appareil doit être utilisé conformément aux prescriptions afin d éviter les électrocutions incendies dommages corporels et matériels N ouvrez pas le boîtier de l appareil Lisez et respectez les consignes de sécurité fondamentales fournies avec l appare...

Страница 5: ...rument up to date and to be informed about new application notes related to your instrument please send an e mail to the Customer Support Center stating your instrument and your wish We will take care that you will get the right information Europe Africa Middle East Phone 49 89 4129 12345 customersupport rohde schwarz com North America Phone 1 888 TEST RSA 1 888 837 8772 customer support rsa rohde...

Страница 6: ...packing and Checking the Instrument 13 3 4 Setting Up the Instrument 14 3 4 1 Bench Operation 15 3 4 2 Rack Mounting 16 4 Instrument Tour 17 4 1 Overview of Controls 17 4 1 1 Front Panel 17 4 1 2 Rear Panel 19 4 2 Switching On the Instrument 22 5 Trying Out the Instrument 23 5 1 Setting the Output Voltage and Current Limit 23 5 2 Activating the Channels Output 24 6 Maintenance 26 Index 27 ...

Страница 7: ...Contents R S NGP800 4 Getting Started 5601 5603 02 05 ...

Страница 8: ... on maintenance The online version html format of the user manual provides the complete con tents for immediate display on the internet Basic safety instructions Contains safety instructions operating conditions and further important informa tion The printed document is delivered with the instrument Service manual Describes the performance test for checking the rated specifications module replacem...

Страница 9: ...r instrument which you can find on a label on the rear panel Release notes and open source acknowledgment The release notes list new features improvements and known issues of the cur rent firmware version and describe the firmware installation The open source acknowledgment document provides verbatim license texts of the used open source software See www rohde schwarz com firmware ngp800 ...

Страница 10: ...exceeded the output of the affected channel is switched off The channel must cool down to a defined threshold before the output can be switched on again Operations of the other channels are not affected Also the actual oper ating speed of the fans is monitored If a fan is not running e g rotor locked con dition all the outputs will be switched off to prevent overheating The Arbitrary function allo...

Страница 11: ...o control any output channel trigger an event e g start arbitrary or to indicate various conditions e g over current protections The R S NGP800 power supplies are equipped with a color 800 x 480 5 TFT LCD touch screen and a USB and LAN interfaces to control the instrument remotely With wireless LAN WLAN option network connection can also be established wirelessly The R S NGP800 power supplies can ...

Страница 12: ...nstrument casing Read and observe the Basic Safety Instructions delivered as a printed brochure with the instrument Note that the basic safety instructions also contain information on operating conditions that prevent damage to the instrument In addition read and observe the safety instructions in the following sec tions Notice that the data sheet may specify additional operating conditions Risk o...

Страница 13: ...s Electromagnetic interference EMI may affect the measurement results To suppress the generated EMI Use suitable shielded cables of high quality for example LAN cables Note the EMC classification in the data sheet 3 1 Safety This instrument was built in compliance with DIN EN 61010 1 VDE 0411 part 1 safety regulations for electrical instruments control units and Iaboratory equip ment It has been t...

Страница 14: ... a safe operation is no longer possible the instrument must be shut down and secured against any unintended operation Safe operation can no longer be assumed when Instrument shows visible damage Instrument includes loose parts Instrument no longer functions properly After an extended period of storage under unfavorable conditions e g out doors or in damp rooms After rough handling during transport...

Страница 15: ...n the positions specified by the manufacturer without the product s ventilation being obstructed If the manufacturer s specifications are not observed this can result in electric shock fire and or serious personal injury and in some cases death Provide adequate airflow Do not block the air intake at the front and side of the instrument or the exhaust at the rear Install the instrument on a locatio...

Страница 16: ... 5 C to 40 C Storage temperature range 20 C to 70 C Humidity noncondensing 5 to 95 Display TFT 5 800 pixels x 480 pixels WVGA Touch Rack installation R S ZZA GE23 rack adapter 2U P N 5601 4059 00 Dimensions W x H x D 362 mm x 100 mm x 451 mm 14 25 x 3 94 x 17 76 Weight R S NGP802 822 2 channel 7 5 kg 16 5 lb R S NGP804 814 824 4 channel 8 0 kg 17 6 lb 3 3 Unpacking and Checking the Instrument Unpa...

Страница 17: ...ave the original packaging use sufficient padding to pre vent the instrument from moving around inside the box Pack the instru ment in antistatic wrap to protect it from electrostatic charging Secure the instrument to prevent any movement and other mechanical effects during transportation Delivery package The package contents contain the following items R S NGP800 power supply Four power cables Tw...

Страница 18: ...low vents are unimpeded Operating the instrument with insufficient airflow or outside the allowable ambient temperature can disrupt the operation and even cause damage 3 4 1 Bench Operation On a benchtop the R S NGP800 power supply can either lie flat or stand on its feet As shown in Figure 3 1 feet on the bottom can be folded out to set the instrument in an inclined position Figure 3 1 Inclined p...

Страница 19: ...tability of the instrument Never shift the instrument when the feet are folded out When the feet are folded out do not work under the instrument or place anything underneath The feet can break if they are overloaded The overall load on the fol ded out feet must not exceed 250 N 3 4 2 Rack Mounting The instrument can be installed in 19 rack using the rack adapter R S ZZA GE23 P N 5601 4059 00 Proce...

Страница 20: ...nstrument 22 4 1 Overview of Controls 4 1 1 Front Panel The front panel of the R S NGP800 power supply is shown in Figure 4 1 The function keys and navigation controls are located beside the display The various connectors are located at the right of the display The following power supply models are available Table 4 1 Power supply models Models Number of output channels NGP802 NGP822 2 NGP804 NGP8...

Страница 21: ...op of individual channel display area of the instrument For a detailed description on screen layout see section Display Overview in the User Manual Rotary knob and back key 2 The rotary knob and back key are used for menu navigation and value adjustment in the instrument For a detailed description on navigation see section Rotary Knob and Back Key in the User Manual Output and channel keys 3 Depen...

Страница 22: ...e In normal state all the internal modules are powered up and the instrument will startup to operate normally The LED illumina tion is turned off in this state USB connector 7 USB Type A connector is provided for connecting a USB flash drive to perform software update store logging data or screen captures It can also be used for an external USB mouse connector Menu control keys 8 The menu control ...

Страница 23: ...ated 2 pole rocker switch 9 Main supply cable Use only the power cable that was supplied with the instrument Using other types which might have inadequate rating can cause overheating of the power cable resulting in fire The power cable provides the earth ground connection through the third ground conductor Operate the instrument only on authorized safety sockets which provide earth connection The...

Страница 24: ...ut terminals Either the channel output terminals at the front panel or rear panel can be used Using both terminals at the same time can cause instrument malfunc tion The channel terminal blocks contain connections to both outputs and remote sense Sense Sense Terminal block for channel 3 and channel 4 are only available for a 4 channel instrument Digital I O analog input connector 15 A 16 pin termi...

Страница 25: ... to turn on the instrument The instrument performs a system check boots the operating system and starts the R S NGP800 power supply firmware It takes a few seconds for the power supply to complete the initialization before it is ready for use If the instrument does not turn on verify that the power cord is securely plugged in and power is available at the outlet Check if the standby power is lit a...

Страница 26: ...u can perform with the R S NGP800 power supply series 5 1 Setting the Output Voltage and Current Limit 1 Press Home key The R S NGP800 power supply displays the home window 2 Select voltage or current parameter of the desired channel The R S NGP800 power supply displays an on screen keypad to set the value Setting the Output Voltage and Current Limit ...

Страница 27: ...t key or enter key The home window shows the updated voltage and current settings See changes of voltage and current values in channel 1 5 Repeat for other channel if desired 5 2 Activating the Channels Output The output voltages can be switched on or off regardless of the instrument s oper ating mode Activating the Channels Output ...

Страница 28: ... operating mode of the instrument Constant voltage CV Voltage regulated actual current is lesser than setpoint Font color of measured voltage and current is green Constant current CC Current regulated current drawn by the circuit is limited to setpoint Font color of measured voltage and current is red When output is turned off the display font color changes to white and the operat ing mode is not ...

Страница 29: ...ng plastic parts and display The display may only be cleaned with an appropriate glass cleaner Rub the dis play with a dry clean and lint free cloth Do not allow cleaning fluid to enter the instrument Internal battery replacement An internal CR2032 coin cell battery powers the real time clock circuit which pro vides continuous time stamp for the instrument If the battery fails the system clock and...

Страница 30: ...anel 17 Rear panel 19 P Putting into operation 9 Intended operation 12 Safety 10 Unpacking and checking the instrument 13 R Rear panel AC inlet with integrated 2 pole rocker switch 20 Analog input connector 21 Channel connectors 21 Digital I O connector 21 Ethernet connector 22 Ground terminal 21 IEEE 488 GPIB interface 21 Kensington security slot 21 USB connectors 22 Release notes 6 S Safety 10 S...

Отзывы: