Remote Control Commands
R&S
®
NGA100
87
User Manual 5601.8919.02 ─ 03
ON | 1
Output state will be turned on.
OFF | 0
Output state will be turned off.
*RST:
OFF | 0
Example:
INST OUT1
OUTP ON
Ch 1 and output state will be activated; i.e.
Ch 1
and
Output
key
on the front panel will be illuminated.
OUTP?
-> 1
Return the output state.
OUTPut:FUSion
<arg0>
Sets or queries the output fusion state for 2-channel model.
Parameters:
<arg0>
OFF | SERies | PARallel
OFF
Output fusion state is off.
SERies
Output fusion state is set to series.
PARallel
Output fusion state is set to parallel.
Example:
OUTP:FUS SER
OUTP:FUS?
-> SER
Output fusion state is set to series.
OUTPut:GENeral
<arg0>
This command activates or queries the instrument master output state.
If the master output state is activated, the
Output
key on the front panel will be illumi-
nated.
Parameters:
<arg0>
{OFF | ON | 0 | 1}
ON | 1
Output state will be activated
OFF | 0
Output state will be deactivated