
Remote Commands
R&S
®
EVSG1000
205
User Manual 1178.6227.02 ─ 04
Manual operation:
See
SETUP:SPEAKER
<State>
This command activates/deactivates the speaker.
Parameters:
<State>
ON | OFF
Return values:
<State>
READY.
The command was executed successfully.
Manual operation:
See
SETUP:VOLUME
<output volume>
This command specifies the AF output volume.
Parameters:
<output volume>
Range:
0 to 100
Default unit: %
Return values:
<State>
READY.
The command was executed successfully.
Manual operation:
See
SQUELCH?
SQUELCH
<Level>
This command gets or sets the squelch level of the active mode ("ILS LOC","ILS GP",
"ILS MB", "VOR" or "COM" mode).
Parameters:
<Level>
Squelch level of active mode
Default unit: dBm
Return values:
<State>
READY.
The command was executed successfully.
Manual operation:
See
13.1.6
Retrieving Instrument Information
The following commands are required to retrieve information on the instrument and
operation status.
Common Instrument and Measurement Setup