Remote Commands in the Receiver Application
R&S
®
ESW
564
User Manual 1177.6298.02 ─ 08
Manual operation:
See
CALCulate<n>:LIMit<li>:CONTrol:OFFSet
<Offset>
This command defines an offset for a complete limit line.
Compared to shifting the limit line, an offset does not actually change the limit line defi-
nition points.
Suffix:
<n>
.
irrelevant
<li>
Parameters:
<Offset>
Numeric value.
The unit depends on the scale of the x-axis.
*RST:
0
Default unit: HZ
Manual operation:
See
CALCulate<n>:LIMit<li>:COPY
<Line>
This command copies a limit line.
Suffix:
<n>
.
<li>
Parameters:
<Line>
1 to 8
number of the new limit line
<name>
String containing the name of the limit line.
Example:
CALC:LIM1:COPY 2
Copies limit line 1 to line 2.
CALC:LIM1:COPY 'FM2'
Copies limit line 1 to a new line named FM2.
Manual operation:
See
CALCulate<n>:LIMit<li>:DELete
This command deletes a limit line.
Suffix:
<n>
.
<li>
Manual operation:
See
Analysis