![Rohde & Schwarz ESRP Скачать руководство пользователя страница 102](http://html1.mh-extra.com/html/rohde-and-schwarz/esrp/esrp_getting-started_1477719102.webp)
Basic Measurement Examples
R&S
®
ESRP
102
Getting Started 1316.4697.02 ─ 07
Table 7-6: Signal generator settings (e.g. R&S SMU)
Frequency
890 MHz
Level
0 dBm
Modulation
GSM, one timeslot activated
The measurement is based on the setting in the example above for measuring
the power of the GSM during the activation phase.
1. Switch off the power measurement.
a) Press the [MEAS] key.
b) Press the "All Functions Off" softkey.
2. Increase the time resolution to 100 µs.
a) Press the [SWEEP] key.
b) Press the "Sweeptime Manual" softkey and enter
100 µs
.
3. Using the trigger softkey, shift the rising edge of the GSM burst to the center
of the screen.
a) Press the [TRIG] key.
b) Press the "Trigger Offset" softkey.
Measurements in Zero Span