2.3 Connection Terminals
Fig. 3 shows the pin assignment of the D-Sub-25 connectors of an R&S ENY81 ISN
basic network with four symmetrical pairs. The drawing in the middle shows an RJ-45
jack with EIA/TIA T568B pin assignment. The 1 mm socket area shown on the right
can be used for any desired assignment of the RJ-11/RJ-45 jacks.
11
'D'-SUB-25-JACK
RJ45-JACK
13
12
10
9
8
7
6
5
4
3
2
1
14
15
16
17
18
19
20
21
22
23
24
25
pair 3
pair 2
1
8
Cross Connector
pair 1
pair 4
2 3 4 5 6 7
pair 1
pair 3
pair 2
pair 4
pair 2
pair 3
pair 1
pair 4
bl
ac
k
red
green
blue
yellow
Fig. 3
Connector assignments
3 Functional Test of the R&S ENY81
Asymmetrical impedance and phase, voltage division factor, longitudinal conversion
loss and decoupling attenuation can be measured using a vector network analyzer and
the R&S ENY-FTS functional test set (order no. 1309.8703.03). If impedance is not
measured, a test receiver with a tracking generator together with the R&S ENY-FTS
functional test set will be sufficient. The R&S ENY-FTS comes with a detailed
description of the calibration and test procedure.