![Rohde & Schwarz 395.0512.02 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/rohde-and-schwarz/395-0512-02/395-0512-02_manual_1477800009.webp)
Voltage Sensors ¸URV5-Z
5
Accessories for RF probe
DC Probe ¸URV5-Z1
The low input capacitance of the DC
Probe ¸URV5-Z1 makes it particularly
suitable for measurements in RF circuits.
Since the probe is virtually non-loaded,
the circuit under test remains largely
unaffected. This prevents the operating
point of active circuits from being shifted,
which can occur with high capacitive
loading.
The DC Probe ¸URV5-Z1, 1 mV to 400 V, 3 pF
÷÷
9 M
:
Accessory Set ¸URV-Z6
20 dB and 40 dB plug-on dividers for extending the voltage measurement range and
reducing the input capacitance to 100 V/1 pF or 1000 V/0.5 pF. BNC adapter for level
measurements in 50
:
coaxial lines (see also Insertion Units ¸URV5-Z2/-Z4).
Adapters ¸URV-Z50 and ¸URV-Z3
With integrated termination for power measurements on matched sources, the
adapters make the probe a power sensor with an extremely wide dynamic range of
93 dB. For increasing the measurement accuracy with the 50
':
adapter connected,
frequency response correction data is stored in each probe.
20/40 dB plug-on dividers and BNC adapter
¸URV-Z50: 50
:
, 20 kHz to 1 GHz,
1 nW to 2 W
¸URV-Z3: 75
:
, 20 kHz to 500 MHz,
0.5 nW to 1.3 W