Voltage Sensors ¸URV5-Z
9
Measurement uncertainties
Values in dB and in % (in parentheses; referenced to measured voltage)
With 75
:'
Adapter
¸URV-Z3
13)
20 kHz to 50 kHz
>50 kHz to 100 kHz
>100 kHz to 200 kHz
>0.2 MHz to 32 MHz
>32 MHz to 100 MHz
>100 MHz to 200 MHz
>200 MHz to 500 MHz
#
0.2/+0.9
11)
(
#
2.3/+10)
11)
ρ
0.2
(
ρ
2.3)
ρ
0.16
(
ρ
1.8)
ρ
0.11
(
ρ
1.3)
ρ
0.2
(
ρ
2.3)
ρ
0.38
(
ρ
4.3)
#
1/+1.1
(
ρ
12)
–
–
–
–
–
–
–
Type
Frequency range
With frequency response correction
10)
up to1 V (20 mW/+13 dBm)
With frequency response correction
10)
above 1 V (20 mW/+13 dBm)
10 V Insertion Unit
¸URV5-Z2
14)
at ¸URV35,
¸URV55,
¸NRVS, ¸NRVD
9 kHz to 20 kHz
!
20 kHz to
'
50 kHz
!
50 kHz to 100 kHz
!
100 kHz to 100 MHz
!
100 MHz to 200 MHz
!
200 MHz to 500 MHz
!
0.5 GHz to 1.0 GHz
!
1.0 GHz to 1.6 GHz
!
1.6 GHz to 2.0 GHz
!
2.0 GHz to 2.4 GHz
!
2.4 GHz to 3.0 GHz
0.35
11)
(4.0)
11)
0.20
11)
(2.3)
11)
0.17
(2.0)
0.13
(1.5)
0.17
(2.0)
0.20
(2.3)
0.25
(2.9)
0.30
(3.5)
0.35
(4.0)
0.40
(4.6)
0.50
(5.8)
0.20
11)
(2.3)
11)
0.17
11)
(2.0)
11)
0.17
(2.0)
0.13
(1.5)
0.17
(2.0)
0.25
(2.9)
0.30
(3.5)
0.40
(4.6)
0.50
(5.8)
0.60
(6.9)
0.75
(8.6)
10 V Insertion Unit
¸URV5-Z2
14)
at ¸URV5, ¸NRV
!
9 kHz to 20 kHz
!
20 kHz to 50 kHz
!
50 kHz to 100 kHz
!
100 kHz to 100 MHz
!
100 MHz to 200 MHz
!
200 MHz to 500 MHz
!
0.5 GHz to 1.0 GHz
!
1.0 GHz to 1.6 GHz
!
1.6 GHz to 2.0 GHz
!
2.0 GHz to 2.4 GHz
!
2.4 GHz to 3.0 GHz
0.45
11)
(5.2)
11)
0.20
11)
(2.3)
11)
0.17
(2.0)
0.13
(1.5)
0.20
(2.3)
0.25
(2.9)
0.35
(4.0)
0.45
(5.2)
0.55
(6.3)
0.65
(7.5)
0.85
(9.8)
0.30
11)
(3.5)
11)
0.20
11)
(2.3)
11)
0.17
(2.0)
0.13
(1.5)
0.20
(2.3)
0.30
(3.5)
0.40
(4.6)
0.55
(6.3)
0.65
(7.5)
0.80
(9.2)
1.05
(12)
Up to 10 V (2 W/+33 dBm)
Above 10 V (2 W/+33 dBm)
100 V Insertion Unit
¸URV5-Z4
14)
at ¸URV35,
¸URV55, ¸NRVS,
¸NRVD
100 kHz to 200 kHz
!
200 kHz to 500 kHz
!
500 kHz to 1 MHz
!
1 MHz to 3 MHz
!
3 MHz to 200 MHz
!
200 MHz to 500 MHz
!
0.5 GHz to 1 GHz
!
1.0 GHz to 1.6 GHz
!
1.6 GHz to 2.0 GHz
!
2.0 GHz to 2.4 GHz
!
2.4 GHz to 3.0 GHz
1.50
11)
(18)
11)
0.60
11)
(6.9)
11)
0.20
11)
(2.3)
11)
0.17
(2.0)
0.13
(1.5)
0.17
(2.0)
0.20
(2.3)
0.30
(3.5)
0.35
(4.0)
0.45
(5.2)
0.65
(7.5)
0.50
11)
(5.8)
11)
0.25
11)
(2.9)
11)
0.17
11)
(2.0)
11)
0.13
(1.5)
0.13
(1.5)
0.20
(2.3)
0.25
(2.9)
0.40
(4.6)
0.50
(5.8)
0.70
(8.1)
1.05
(12)
100 V Insertion Unit
¸URV5-Z4
14)
at ¸URV5, ¸NRV
100 kHz to 200 kHz
!
200 kHz to 500 kHz
!
500 kHz to 1 MHz
!
1 MHz to 3 MHz
!
3 MHz to 200 MHz
!
200 MHz to 500 MHz
!
0.5 GHz to 1.0 GHz
!
1.0 GHz to 1.6 GHz
!
1.6 GHz to 2.0 GHz
!
2.0 GHz to 2.4 GHz
!
2.4 GHz to 3.0 GHz
2.20
11)
(26)
11)
0.80
11)
(9.2)
11)
0.25
11)
(2.9)
11)
0.17
(2.0)
0.13
(1.5)
0.17
(2.0)
0.25 (2.9)
0.45
(5.2)
0.60 (6.9)
0.80 (9.2)
1.15
(14)
0.80
11)
(9.2)
11)
0.40
11)
(4.6)
11)
0.20
11)
(2.3)
11)
0.13
(1.5)
0.13
(1.5)
0.20
(2.3)
0.30
(3.5)
0.55
(6.3)
0.70
(8.1)
1.00
(12)
1.50
(18)
Type
Voltage measurement range
Measurement uncertainty
9)
DC Probe
¸URV5-Z1
1 mV to 100 V
!
100 V to 400 V
ρ
0.013 (
ρ
0.15)
ρ
0.030 (
ρ
0.35)
Type
Frequency range
Without frequency response correction
9
)
With frequency response correction
10)