Notes on Safety

R&S

®

RT-ZC10

8

User Manual 1409.7808.02 ─ 03

Risk of instrument damage

To avoid damage to the device, protect it from vibration or shock during
transport and handling, and be especially careful to avoid dropping.

Do not store or use the device where it could be exposed to direct sun-
light, high temperature, humidity, or condensation. Under such condi-
tions, the device may be damaged and insulation may deteriorate so
that it no longer meets its specifications.

Before using the device the first time, verify that it operates normally to
ensure that no damage occurred during storage or shipping. If you find
any damage, contact your dealer or R&S representative.

This device is not designed to be entirely water- or dust-proof. To avoid
damage, do not use it in a wet or dusty environment.

The sensor head is a precision assembly including a molded compo-
nent, a ferrite core, and a Hall effect element. It may be damaged if sub-
jected to sudden changes in ambient temperature, or mechanical strain
or shock, and therefore great care should be exercised in handling it.

Do not apply a static electricity or other source of high voltage to the
sensor. Doing so may damage the internal Hall elements and circuitry of
the sensor.

The mating surfaces of the sensor head are precision, and should be
treated with care. If these surfaces are scratched, performance may be
impaired.

Foreign substances such as dust on the contact surfaces of the sensor
head can cause acoustic resonance and degrade measurement, so
clean it by gently wiping with a soft cloth.

When the power is on, keep the core section of the sensor closed,
except when clamping it onto the conductor to be measured. The mating
surface of the core section can be scratched while it is open.

To avoid damaging the sensor cable and power supply cable, do not
bend or pull the cables.

Avoid stepping on or pinching the cable, which could damage the cable
insulation.

Keep the cable well away from heat sources, as bare conductors could
be exposed if the insulation melts.

Содержание 1409.7750.02

Страница 1: ...R S RT ZC10 Current Probe User Manual 1409780802 Version 03 9 82...

Страница 2: ...89 41 29 0 Email info rohde schwarz com Internet www rohde schwarz com Subject to change data without tolerance limits is not binding R S is a registered trademark of Rohde Schwarz GmbH Co KG Trade na...

Страница 3: ...Probe 11 3 Putting into Operation 13 3 1 Preparing the Measurement 13 3 2 Connecting the Probe to the Oscilloscope 15 3 3 Demagnetizing and Zero Adjustment 16 3 4 Connecting the Probe to the DUT 17 4...

Страница 4: ...Contents R S RT ZC10 4 User Manual 1409 7808 02 03...

Страница 5: ...rence Risk of physical injury This device is designed to comply with IEC 61010 Safety Standards and has been thoroughly tested for safety before shipment However mishan dling during use could result i...

Страница 6: ...and never measure any current that exceeds the rated current Use with high frequencies or strong magnetic fields may cause the device to become abnormally hot result ing in fire equipment damage or b...

Страница 7: ...minal other than that to which this device is connected do not connect the ground side terminal to any nonground potential Otherwise short circuit current flows through the R S RT ZA13 probe power su...

Страница 8: ...may be damaged if sub jected to sudden changes in ambient temperature or mechanical strain or shock and therefore great care should be exercised in handling it Do not apply a static electricity or ot...

Страница 9: ...2 03 Strong electromagnetic fields Correct measurement may be impossible in the presence of strong mag netic fields such as near transformers and high current conductors or in the presence of strong e...

Страница 10: ...ents Easy protection function to avoid self heating during excessive input Unique thin film Hall effect element 2 3 Inspecting the Contents Inspect the package for damage Keep the package and the cush...

Страница 11: ...case R S RT Zxx data sheet Calibration certificate Documentation of calibrated values 2 4 Description of the Probe 1 Sensor head clamp 2 Sensor 3 Slider 4 Lever 5 Lock Unlock indicator 6 Indicator of...

Страница 12: ...clamp Lever The lock mechanism keeps the clamp closed Demagnetizing switch DEMAG This demagnetizes the core if it has been magnetized by switching the power on and off or by an excessive input Always...

Страница 13: ...ted internally Use a high impedance input of the measuring instrument With an input impedance of 50 accurate measurement is not possible If using BNC banana plug adapters or similar to connect to inpu...

Страница 14: ...ecurely Figure 3 1 Oscilloscope inputs The current waveform of the measured conductor is output at a constant rate 0 01 V A 7 Configure the probe connection at the oscilloscope Make sure to set the fo...

Страница 15: ...1 to the Rohde Schwarz probe interface of the oscilloscope 2 The probe snaps in when connected properly to the port Figure 3 2 Connecting the probe to the Rohde Schwarz oscilloscope To disconnect the...

Страница 16: ...R S RT ZC10 When power is turned on a demagnet izing waveform is initially applied to the output This is intentional in the design and not a fault Risk of instrument damage Make sure to open the clam...

Страница 17: ...the terminator to adjust the trace to the zero position 3 4 Connecting the Probe to the DUT 1 Check that the system is safe and that the preparations described in the pre ceding sections have been ca...

Страница 18: ...urement is not possible The current consumption of clamp on probes depends on the current to be measured Confirm that the total current consumption of the probes does not exceed the rated output curre...

Страница 19: ...ated cur rent is a recommended value that assumes sine wave input under stan dard conditions Self heating may happen if the ambient temperature increases or the measurement current waveform contains o...

Страница 20: ...cal principles Be careful to avoid injury electric shock due to short circuits or damage to the device that may be caused by the increased temperature Do not place any unclamped conductor with an elec...

Страница 21: ...may occur while the power sup ply is on This does not indicate a malfunction Oscillation can be stop ped and operation restored to normal by opening and closing the clamp Acoustic resonance may occur...

Страница 22: ...object 2 Clean the outside of the product using a soft cloth moistened with either distil led water or isopropyl alcohol Keep in mind that the casing is not waterproof Note Do not use cleaning agents...

Страница 23: ...ider the following 1 Use a sufficiently sized box 2 Protect the product from damage and moisture e g with bubble wrap 3 Use some kind of protective material e g crumpled newspaper to stabilize the pro...

Страница 24: ...Maintenance and Service R S RT ZC10 24 User Manual 1409 7808 02 03 4 5 Discarding the Product Handle and dispose the product in accordance with local regulations Discarding the Product...

Страница 25: ...ly R S RT ZC10 25 User Manual 1409 7808 02 03 5 R S RT ZA13 Probe Power Supply This unit is a special purpose power supply for the current probes You can connect up to four current probes to the power...

Отзывы: