R&S ENY81-CA6
Operation
Operating Manual 1309.8632.14 - 01
8
2.1 Radio Disturbance Measurements in Line with CISPR 22
The ISN consists of a high symmetric basic network (eight-wire ISN) with on the EUT
side implemented longitudinal conversion loss (LCL) of 75 dB to simulate operation
with a category CAT6 cable. For cable categories CAT3 and CAT5, the R&S ENY81
(1309.8503.03) eight-wire coupling network can be obtained separately.
The basic network allows connection to RJ-45 sockets with pin assignments in line with
EIA/TIA T568A or T568B, respectively. Table 1 shows the pin assignment.
Type
Application
Pin assignment in line with EIA/TIA T568B
Pair 1/
Pair 2/
Pair 3/
Pair 4/
Connector
Pin 4,5
Pin 1,2 Pin 3,6
Pin 7,8
R&S ENY81-CA6
Base unit
Gigabit
Ethernet
(1000BaseT)
RJ-45
X
X
X
X
Table 1
Pin assignment of the RJ-45 socket