PR102DR Installation Guide Rev.E.doc

 

2017-09-18 

 

 

12/13 

 

More information on controller programming can be found in the document  Functional description 

of  PRxx2  series  controllers  as  well  as  in  PR  Master  User  Manual,  which  are  available  at 

www.roger.pl

. 

4.4 Firmware update 

The latest versions of firmware and Roger ISP software are available at 

www.roger.pl

In order to 

update firmware it is necessary to connect the device by means of RS485 bus  to communication 
interface  (UT-2USB  or  RUD-1)  and  then  connect  the  interface  to  PC  with  installed  Roger  ISP 
software.  It  is  not  necessary  to  disconnect  the  controller  from  access  control  system,  it  is  only 

required  to  place  FDM  jumper  in  order  to  put  the  device  in  firmware  download  mode.  Therefore 
firmware update can be performed by means of RS485 bus of access control system. 

Firmware update procedure 

 

 Place jumper on FDM pins (see fig. 6) 

 

 Reset device (press RESET button or switch power off/on) 

 

 Start RogerISP software and select communication port (in case of RUD-1 select 

USB-RS485 

Converter

). 

 

Press the button 

Erase

 

 

Once more reset device (place and remove jumper on RST pins or switch power off/on) 

 

 In Firmware window select firmware *.hex file (can be downloaded from 

www.roger.pl

) and 

then select the button 

Program

 

 

After firmware upload remove jumper from FDM pins and reset device (press RESET button or 
switch power off/on) 

Note: If the controller is not responding and LED SYSTEM   (orange) is on after firmware update 

then it is necessary to reset – see 4.2 Memory Reset procedure or update firmware once more. 
 
Note: In case of network system, it is required to restart controller within PR Master software by 
right  clicking  particular  controller  and  selecting  the  option 

Restart  controller  and  verify 

version

5.

 

O

RDERING INFORMATION

 

Table 6. Ordering information 

PR102DR 

Access controller in enclosure adapted for installation on DIN 35mm rail. 

PR102DR-BRD  Electronic module of PR102DR controller. 

ME-2-D 

Metal enclosure with 13.8VDC/3.5A power supply unit, adapted for 8 x PR102DR 
controllers. 

ME-5-S 

Metal enclosure with 13.8VDC/11A power supply unit, adapted for 18 x PR102DR 
controllers. 

PS-15DR 

13.8VDC/1.5A power supply unit adapted for installation on DIN 35mm rail. 

CPR32-NET-
BRD 

Electronic module of network controller . 

UT-4DR 

Ethernet-RS485 communication interface. 

UT-2USB 

USB-RS485 communication interface. 

RUD-1 

Portable USB-RS485 communication interface with 12VDC/0.12A output. 

 

Содержание PR102DR

Страница 1: ...mware version 1 18 6 or newer Hardware version 1 0 Document version Rev E 2016 ROGER sp z o o sp k All rights reserved This document is subject to the Terms of Use in their current version published at the www roger pl website of the Roger sp z o o sp k company hereinafter referred to as ROGER ...

Страница 2: ...3 7 1 Inputs 8 3 7 2 Relay output 8 3 7 3 General purpose output 8 3 8 Installation guidelines 8 4 Configuration 9 4 1 Controller address 9 4 1 1 Addressing by means of jumpers 9 4 1 2 Addressing during firmware update Fixed ID 10 4 1 3 Addressing during Memory Reset procedure 10 4 1 4 Addressing by means of PR Master software 10 4 2 Memory Reset procedure 10 4 2 1 Simplified Memory Reset Procedur...

Страница 3: ...r connection of external reader PR102DR controllers are not equipped with built in reader and they require connection of external reader s operating in RACS CLK DTA PRT series terminals Controllers can be configured with PR Master software installed on computer and they can be connected to computer by means of communication interface e g UT 2USB UT 4DR RUD 1 or by means of CPR32 NET network contro...

Страница 4: ...s Table 2 PR102DR terminals Terminal Description Terminal Description DTA RACS CLK DTA comm bus IN1 IN1 input line CLK RACS CLK DTA comm bus GND Ground B RS485 communication bus 12V 12VDC power supply A RS485 communication bus NO REL1 relay output NO OUT1 OUT1 output line COM REL1 relay common terminal IN2 IN2 input line NC REL1 relay output NC ...

Страница 5: ...PR102DR Installation Guide Rev E doc 2017 09 18 5 13 Fig 2 PR102DR connection diagram ...

Страница 6: ...re and during firmware update procedure Table 3 PR102DR front panel DC DC supply ARMED DISARMED Current arming mode OPEN Door unlocked SYSTEM Various signalling functions LINK Data transmission on RS485 bus Fig 3 PR102DR front panel 3 2 2 PR102DR BRD controller According to fig 4 PR102DR BRD is equipped with 4 LED indicators and RST button on its PCB The button can be used to restart the controlle...

Страница 7: ...age surge can occur when current flow is interrupted and it can interfere with the controller electronic components In extreme cases it may result in improper operation of the controller or even freeze Moreover overvoltage condition causes quicker wear of relay contacts In order to limit this adverse effect it is necessary to use a general type semiconductor diode e g 1N4007 one piece of such diod...

Страница 8: ...d output lines Functions are assigned to inputs and outputs by means of PR Master software Default function for REL1 relay output is door unlocking 3 7 1 Inputs All inputs IN1 IN2 of controllers have identical electric structure and can be configured as NO or NC lines using PR Master software The NO input is triggered by shorting it to supply minus GND while the NC input must be normally shorted t...

Страница 9: ... ID number from range 00 99 Two or more devices with the same address result in communication conflict and make a proper communication with these devices impossible Following addressing methods are available By means of jumpers During update of controller firmware by means of Roger ISP software so called Fixed ID Manually during Memory Reset procedure By means of PR Master software The first two m...

Страница 10: ...an be configured during Memory Reset procedure see 4 2 Memory Reset procedure Note Software address is effective only if the address set with jumpers on the controller is in range of 100 127 and FixedID is None 4 1 4 Addressing by means of PR Master software Software address can be configured by means of PR Master software In such case connect the controller to PC via communication interface e g U...

Страница 11: ...e requires connection of PRT series reader with keypad e g PRT12LT Remove connections to CLK and DTA terminals Connect CLK with DTA Restart the controller press RESET button or switch power supply off on LED OPEN shall start to pulsate Disconnect CLK and DTA Connect PRT series reader with keypad e g PRT12LT to CLK and DTA lines without switching power supply off and take further steps by means of ...

Страница 12: ...RST pins or switch power off on In Firmware window select firmware hex file can be downloaded from www roger pl and then select the button Program After firmware upload remove jumper from FDM pins and reset device press RESET button or switch power off on Note If the controller is not responding and LED SYSTEM orange is on after firmware update then it is necessary to reset see 4 2 Memory Reset pr...

Страница 13: ...user is obliged to deliver equipment to the designated collection points of electric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste contributes to the protection of the natural resources and is safe to health and the environment Weight of the equipment is s...

Отзывы: