Safety input and command status (TEST mode)
;MXLRSGYVVIRXP]EGXMZIGSQQERHWTVIWWXLI8)78FYXXSRERHGLIGOXLIJSPPS[MRK
DISPLAY POSSIBLE CAUSE
ACTION BY SOFTWARE
PHYSICAL CORRECTIVE ACTION
The safety
STOP
contact is open.
-
Install a
STOP
button (NC) or jumper the
ST
contact with the
COM
contact.
Sensing edge
COS1
not connected
or incorrectly connected.
Set the parameter
if not used
or to disable.
Jumper contact
COS1
with contact
COM
,
if not used or to disable
Sensing edge
COS2
not connected
or incorrectly connected.
Set the parameter
if not used
or to disable.
Jumper contact
COS2
with contact
COM
,
if not used or to disable.
Photocell
FT1
not connected or in-
correctly connected.
Set the parameter
e
if
not used or to disable.
Jumper contact
FT1
with contact
COM
, if
not used or to disable. Check connection
referring to relative connection diagram
Photocell
FT2
not connected or in-
correctly connected.
Set the parameter
e
if
not used or to disable.
Jumper contact
FT2
with contact
COM
, if
not used or to disable. Check connection
referring to relative connection diagram
)(
At least 3 limit switches in open con-
tact state or not connected.
-
Check connection of limit switches.
)$
Both gate leaves at open limit switch.
-
-
Open limit switch not connected.
-
Check connection of limit switches.
)&
Both gate leaves at closed limit
switch.
-
-
Closed limit switch not connected.
-
Check connection of limit switches.
)
LEAF 1 limit switches not connected
or incorrectly connected.
-
Check connection of limit switches.
)
LEAF 2 limit switches not connected
or incorrectly connected.
-
Check connection of limit switches.
LEAF 1 open limit switch not con-
nected or incorrectly connected.
Or LEAF 1 is open.
-
Check connection of limit switches.
LEAF 1 closed limit switch not con-
nected or incorrectly connected.
Or LEAF 1 is closed.
-
Check connection of limit switches.
LEAF 2 open limit switch not con-
nected or incorrectly connected.
Or LEAF 2 is open.
-
Check connection of limit switches.
LEAF 2 closed limit switch not con-
nected.
Or LEAF 2 is closed.
-
Check connection of limit switches.
SS
If occurs with no voluntary com-
mand, the contact (N.O.) may be
faulty or one of the buttons may be
incorrectly connected.
-
Check
PP
-
COM
contacts and connec-
tions to buttons.
&+
-
Check
CH
-
COM
contacts and connec-
tions to buttons.
DS
-
Check
AP
-
COM
contacts and connec-
tions to buttons.
SH
-
Check
PED
-
COM
contacts and connec-
tions to buttons.
2U
If occurs with no voluntary com-
mand, the contact (N.O.) may be
faulty or the timer may be incorrectly
connected.
-
Check
ORO
-
COM
contacts. Contact
must not be jumpered if not used.
N.B.
Press
TEST
button to exit from the
TEST
Mode.