Parameter
Number
Description of parameter function
parameter value → Behaviour of the parameter
Default Value
INPUT
Showing of input status
(picture 5)
LL
Configuration level
0 → BASIC shows You only a part of the parameters (ones not marked by A)
1 → ADVANCED shows You all parameters
0
02
Automatic closing after pause time
0 → OFF not automatic closing
1-15 → numers of reclosing chance
99 → it always reclosing
0
03
Automatic closing after blackout
0 → OFF it does not close when the power comes back
1 → ON it closes when the power comes back
0
04
STEP BY STEP (PP)
0 → OPEN – STOP – CLOSE – STOP – OPEN - STOP
1 → PP CONDOMINIUM, when it is completely opens, it renews pause time
2 → PP CONDOMINIUM, when it is completely opens, it closes
3 → OPEN – CLOSE – OPEN - CLOSE
4 → OPEN – CLOSE – STOP – OPEN - CLOSE
0
05
A
Preflashing
0 → flashing light start to flash when the gate moves
1-60 → SECOND anticipate time of preflashing before the gate moves
99 → in opening not enables, 5 seconds preflashing in closing
0
06
A
PP Condominium Pedestrian
0 → pedestrian makes: OPEN – STOP – CLOSE – STOP – OPEN - STOP
1 → pedestrian always open
0
07
A
Deadman
0 → normal function
1 → the gate moves only if You press the button OPEN and CLOSE
0
08
A
Open gate led (SC)
0 → when the gate is closed the led is switch off, otherwise the led is fixed on
1 → slow flashing in opening, fast in closing and fixed when the gate is completely open, double flashing
when the gate stopped in the middle of the travel
0
10
Length travel learning
(You have to do that when the gate is in the middle of his travel)
To make the travel lenght learning You have to set the value to 1 and You have to confirm it by S3, after we
see flashing all numbers and push the PP. The motor will make a complete opening and closing in slow-
down, if the process is made in right mode, the parameter comes back to 0. If the display shows You _E, it
means that the process is failed, and You have to repeat it
0
11
A
Slow-down travel
1-20 → PERCENTAGE of slow-down travel respect of normal speed
10
13
A
Tollerance of the position in which the gate it is consider closed
1-99 → MILLESIMUM respect of total travel
10
15
A
Lenght of pedestrian travel
1-99 → PERCENTAGE of pedestrian opening respect of normal travel
30
21
Pause time before automatically reclosing.
When one of the photocells is darkened, the timer of pause
time is stopped, when the beam of photocells is restored the timer starts again the counting of pause time.
0-90 → SECONDS of pause time before of automatically reclosing
92-99 → from 92 the second number shows You the MINUTES of pause time before of automatically
reclosing (from 2 to 9 minutes)
30
27
A
Inversion time after the contact with safety edge or anticrushing
0-99 → inversion SECONDS
2
31
Torque level during the normal travel
1-8 → LEVEL (1 = minimum... 8 = maximum)
5
32
A
Torque level during the slow-down
1-8 → LEVEL (1 = minimum... 8 = maximum)
8
33
A
Torque level during the start up
0 → start up not enable
1-8 → LEVEL (1 = minimum... 8 = maximum)
8
34
A
Configuration of start up
to avoid the tear on starting
0 → soft start not enable
1 → soft start
2 → slow soft start
2
12