DLD1/24-DLD2/24 loop detector DIN variant, mounting rail installation
LCD display
«Mode» button
«Data»-button
Terminals
Info LED
1
Loop detector for industrial and commercial
doors and gates, car parks
2
Mechanical mounting in the switch cabinet
3
Electrical connection
DLD1/24-DLD2/24 terminal connection diagram
Safety instructions
1
General
These devices and their accessories may only be operated in compliance with the operating instructions (intended use)!
These devices and their accessories may only be commissioned by trained and qualified personnel.
These devices may only be operated with the intended operating voltages and parameters.
If malfunctions occur that cannot be rectified, shut down the device and send it in for repair.
These devices are only allowed to be repaired by the manufacturer. Tampering and alterations are not permitted. This will invalidate all guarantee and
warranty claims.
The DLD1/24-DLD2/24 is mounted on a 35 mm mounting rail acc. to EN 50 022 in the switch cabinet.
The terminals are pluggable and coded.
A:
Supply
voltage
connection
B:
Loop connection
1-channel device
C:
Loop connection
2-channel device
D:
Alarm output
connection
(optional)
E:
Relay connection
output 1
F:
Relay connection
output 2
AC
AC
A1
A2
31
32
34
n o
n c
com m on
14
11
12
n o
n c
com m on
24
21
22
n o
n c
com m on
L3
L4
L3
L4
L5
L6
1
2
The loop connection wiring to the loop detector must be twisted at least 20 times per meter.
Please ensure the unit is wired properly with correct input voltage and all terminals are connected according to the wiring diagram on the label.
1-loop device
Relay assignment:
Output connection
diagram:
Output 1
E
Output 2
F
Alarm output
D
2-loop device
Relay assignment:
Output connection
diagram:
Output 1+2
E, F
Alarm output
D
Output connection options (depending on the options ordered):
3.1
ENGLISH
General
Explanation of the LCD display
Explanation of the LED
Standard display
1-loop device
Standard display
2-loop device
Control button
Control button
1
1
2
Mode
Sim1
Data
Sim2
1
2
Loop 2
Example:
Parameter «h»
set
Function
E
xample:
T
ime
f
unction set
Loop 1
Info
Red + green:
Start-up phase
Green:
Operation
Red + green:
Configuration
Flashing green: Output 1 and/or
2 activated
Flashing red:
Error
Flashing
red + green:
Simulation
The settings of the DLD1/24-DLD2/24 devices in this chapter are shown and explained for the 1-loop device. The settings for loop 2 of a 2-loop device
should be made using the corresponding method.