35
78
00
Flashing configuration
00
FIXED (the intermittent operation is carried out by the electronics of the flashing)
01
slow intermittent activation
02
slow intermittent when opening; quick intermittent activation when closing
NOTE: parameter
7-
in simplified mode
The flashing starts when there is a movement phase; you can have continued activation (for flashing
lights with electronics timed on-board) or controlled directly by the control unit (for flashing lights
with a simple lamp).
79
60
Duration courtesy light
00
OFF (deactivated)
01
PULSE (brief activation at the start of each operation)
02
ACTIVE DURING THE ENTIRE OPERATION
03
-
90
SECONDS OF ILLUMINATION AFTER THE END OF THE OPERATION
92
-
99
FROM 2 TO 9 MINUTES AFTER THE END OF THE OPERATION
80
00
Clock configuration
00
When the clock input is closed (ORO) it opens and then ignores all the commands
01
When the clock input is closed (ORO) it opens and accepts all the commands
If you choose par.
A1
03
and
72
01
the parameter is not displayed.
81
00
Closure enabling guaranteed
00
DEACTIVATED (NOTE: as a result par
82
is not displayed)
01
ENABLED
Enabled when you want the wings to never remain open in unexpected situations; for example for
an activation not due to a step-by-step command keeping away from the gate while it was closing,
or due to a strong gust of wind which activates the anti-crushing protection, the gates would remain
open while waiting for a new command.
After a time set by parameter
82
the control unit activates a pre-flashing of 5” (even if not enabled
from par.
A5
) and then by a closing command.
The function will only be able to intervene if a STOP command has been given (from the push-button
pad) or the safety edge has intervened and the number set by parameter
a2
, has been exceeded, or
control of the position has been lost (needs to be repositioned).
82
00
Waiting time to activate the closure guaranteed
00
-
90
SECONDS
92
-
99
from 2 to 9 MINUTES
90
00
Restoring standard factory values
After having displayed the number
90
, press the + and - buttons simultaneously for 4 seconds, the
display shows
rE
S-
flashing which signals a standard factory values reset has taken place
(indicated next to the parameter numbers).
WARNING!
A1
is not restored
WARNING! After the reset, check that the parameters are adjusted to the type of installation.
Содержание BRUSHLESS B70/2DC
Страница 114: ...114 ...
Страница 115: ...115 ...