background image

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Model - FC-70 

Plus 

P/N 121-000-1109 

 
 

Circuit Board P/N 24-214 

 
 
 

 

Input:

 

120 VAC, 50/60 HZ. 

(Operating range 100-130 VAC) 

 

Single Unit Fuse Size: 5 AMPS

 

 

Output: 0-120 VAC 

 

 

© 2015 RODIX 

INC

.

 

Warning: To avoid shock, remove power 
before making any changes to the circuit 
board settings or connections. The 
control is not isolated from the power 
line.  

 

1.  SELECT THE PULSE SETTING 

Match the control’s pulse mode to the feeder’s tuning: 
A.   For 60 pulse output - Set DIP switch (S1, position 

1) to 60 on the circuit card.   

B.   For 120 pulse output - Set DIP switch (S1, 

position 1) to 120 on the circuit card. 

C.  For 60 Reverse pulse setting see the “Feature 

Programming Chart”. The “60 Pulse Reverse” 
feature is useful for reducing mechanical vibration 
interaction between different feeder components 
mounted on the same machine table. To 
determine if there is a feeder interaction, remove 
the power from one feeder. If a feeder interaction 
exists, the feed rate on the other feeder will either 
speed up or slow down.  

D. For 40 pulse output see the “Feature 

Programming Chart”. The 40 Pulse rate can be 
useful in a minority of applications for feeding 
heavy parts. The power output is not as high as 
60 pulse mode.  A vibratory feeder that is 
converted to a lower pulse mode will require 
fewer springs. 

 

2.  AMPLITUDE POT

 

The output power is controlled by the 

AMPLITUDE 

POT

.  It is a logarithmic-tapered power out curve 

(non-linear) that spreads the power broadly across the 

AMPLITUDE POT

. The logarithmic taper power curve 

helps to give maximum "Fine Control" over the output 
speed of the vibratory feeder.  

 

 

3. SETTING THE SOFT-START

 

The start-up rate of the control’s output can be set to 
ramp up to the desired output level instead of starting 
abruptly.  The Soft-start keeps parts from falling off 
the tooling, reduces spring shock, and hammering 

when the control turns ON. Set position 2 of S1 
DIP switch to the ON position to enable the two 
second 

SOFT

 Start function.  Set position 2 of S1 

DIP switch to the OFF position to disable the 

SOFT

 Start function. 

 

4.  REMOTE OFF/ON CONTROL 

A Run Jumper has been installed at the factory as 
shown on the enclosed wiring diagram.  

 

Remote OFF/ON operation of the FC-70 Series 
Feeder Cube

®

 control can be configured to operate 

in one of the following ways. 

 

A.   A 

low current switch

 such as a paddle switch 

can replace the factory-installed Run Jumper 
"J1." The "Run Contact" connects to terminals 
TB2-3 and 4. The contact must be isolated 
and be able to switch 24VDC and 2mA.  The 
control will run when the contact is closed.  
Refer to Section A of the OFF/ON CONTROL 
GUIDE.   

 

B.    Low Voltage DC can be used to turn the 

control  ON and OFF.  Remove jumper "J1" 
from TB2 terminals 3 and 4.  Then connect the 
positive signal (+12 to 24VDC @ 5mA) to TB2 
terminal 2 and the negative to terminal 1 of 
TB2.  The control will now turn ON when the 
DC signal is present at terminals 1 and 2 of 
TB2.  This input is optically isolated. Refer to 
Section B of the OFF/ON CONTROL GUIDE.   

 

There is a “RUN” status LED that lights up when 
either the low current switch is closed or when an 
external low voltage DC signal is applied. The 
control’s output will be ON whenever the “RUN” 
LED is lit and the AMPLITUDE POT is turned up. 

 

5. LINE VOLTAGE COMPENSATION 

Fluctuations in the line voltage can cause a feeder 
bowl to vary its feed rate.  The line voltage 
compensation feature adjusts the control's output 
to help compensate for fluctuations in the supply 
voltage. If it becomes necessary to disable this 
feature, remove resistor “R20” from the circuit 
board.  R20 is located near the Triac labeled Q1. 
With the input power disconnected, a knife can be 
used to cut down through “R20”. 

 

FC-70 24-214.doc 12/23/2015  Page 1 

 

ADJUSTMENTS  

AND SET UP 

RODIX INC. 

FEEDER CUBE

 

FC-90

 

Plus Series

 

GENERAL PURPOSE

 

 

RODIX INC. 

FEEDER CUBE

 

FC-70 SERIES 
General Purpose 

 

Содержание FC-70 Plus Series

Страница 1: ...ing when the control turns ON Set position 2 of S1 DIP switch to the ON position to enable the two second SOFT Start function Set position 2 of S1 DIP switch to the OFF position to disable the SOFT Start function 4 REMOTE OFF ON CONTROL A Run Jumper has been installed at the factory as shown on the enclosed wiring diagram Remote OFF ON operation of the FC 70 Series Feeder Cube control can be confi...

Страница 2: ...y WARRANTY Rodix Control Products are Warranted to be free from defects in material and workmanship under normal use for a period of two years from date of shipment For the full description of the warranty terms and software license please contact the factory For assistance installing or operating your Rdix Feeder Cube please call the factory or visit our web site Technical help is available to an...

Страница 3: ...D GND GND JUMPER OUTPUT ON OFF 60 120 PULSE 0 120 VAC P N 24 214 5 AMP R20 POT COM COM HOT 3 2 1 TB1 4 TB2 J1 3 2 1 LOAD 4 Ext Volts Gnd 12 24 Run R24 R25 120 Soft AMP 60 INPUT 50 60 Hz 120 VAC MALE LINE CORD POWER Bl 14 Wh 14 Gr 14 Bl 14 Wh 14 Gr 14 Bl 14 Wh 20 Wh 14 Bl 14 RODIX INC FEEDER CUBE FC 70 Series WIRING DIAGRAM MODEL INPUT VAC AMPS OUTPUT FC 70 120 VAC 5 0 120 V RODIX INC 2316 23rd Ave...

Страница 4: ...lutions for Electrical Noise 1 Use shielded wires for all I O Input Output signals The I O signals may include 4 20mA input Run input Sensor input 0 5VDC input Interlock input or AUX output The shield drain wire should be tied to the chassis in the Rodix control The drain wire should be kept shorter than 2 Please see the enclosed picture Example of a drain wire termination 2 Never run I O signal w...

Отзывы: