MODEL  FC-48H-PLC 

Plus

Plus

Plus

Plus    

P/N 121-690 

 

Listed, File No. 

E183233

 

 
 

Input: 240 VAC 

 50/60 

HZ. 

 

Output: 0-240 VAC 

 

Single Unit Fuse Size: 15 AMPS 

80% Duty Cycle at Rated AMPS 

 

 

 

© 2000 

RODIX

    

INC

....

 

 

  1.  SELECTING 60 OR 120 PULSE 
 OPERATION 

 
A.    For  60  pulse  output - Set switch (S1) to 60 on 

"master control" P.C. card (No. 24-489).   

B.   For 120 pulse output - Set switch (S1) to 120 on 

"master control" P.C. card. 

 

Note:  Readjust MAX pot after changing pulse 
switch setting.

 

 

 

2.  LIMITING THE MAXIMUM 

 

OUTPUT OF CONTROL

 

 
Adjust the 

MAX

 Output trimpot so that the output to 

the feeder reaches its desired maximum level when 
the 

MAIN CONTROL DIAL

 is turned fully clockwise.  

The 

MAX

 Output trimpot should be adjusted to keep 

the vibratory feeder from hammering when the control 
is turned up to full power. 
 

NOTE:  Output to feeder must be connected and 
the control set for proper output frequency (60 or 
120 pulse) setting.  The Run Jumper must be 
connected as shown on the wiring diagram.

 

 
A.   Power input should be

 OFF

 or disconnected. 

B.   Rotate

 MAIN CONTROL DIAL

 on front cover to 0 

or its minimum setting. 

C.  Open cover to allow access to printed circuit 

card. 

D. Using 

CAUTION

, turn power 

ON

 (no output 

should be present). 

E.   Rotate the 

MAIN CONTROL DIAL

 on front cover 

slowly to its highest setting. 

F.   Adjust the 

MAX

 Output trimpot so that the output 

to the feeder reaches its desired maximum level 
when the 

MAIN CONTROL DIAL

 is turned fully 

clockwise.  Turning the 

MAX

 Output trimpot 

clockwise increases the maximum output 
level. 

 

 

3.  REMOTE OFF/ON CONTROL  

 

Note: a Run Jumper has been installed at the 
factory as shown on the enclosed wiring diagram. 

 

Remote OFF/ON operation of the FC-40 

Plus 

Plus 

Plus 

Plus 

Series

Series

Series

Series

  Feeder Cube

®

 control can be configured 

to operate in one of the following ways. 

 

A.   A low current switch such as a paddle switch 

can replace the factory-installed Run jumper 
"J1."  The "Run Contact" connects to 
terminals 6 and 7. The contact must be able 
to switch 5VDC and 2mA.  The control will 
then run only when the contact is closed.  
Refer to Section A of the OFF/ON CONTROL 
GUIDE.

 

 

B. 

 

Feeder Bowl/Hopper Interlock allows the 

Hopper control to operate only when the Bowl 
is running and the paddle switch contact is 
closed. The 

interlock input

 on terminals 11 

and 12 of TB2 is controlled by the 

interlock 

output

 of a "Parts Sensing Feeder Bowl 

Control" such as an FC-90 

Plus

Plus

Plus

Plus

.  

 

    Remove jumper "J1" of this control from 

terminals 6 and 7.  Connect the Hopper 
Paddle switch to alternate terminals 5 and 6. 
Connect TB2 terminals 11 and 12 of this 
control to the "Parts Sensing Control".  Refer 
to Section B of the OFF/ON CONTROL 
GUIDE. Check specific instructions for the 
"Parts Sensing Control" wiring.    

 

Note: Only use the Bowl/Hopper Interlock with 
a FC-90 and FC-40 Series control.  Two FC-
40 Series controls will not interlock to each 
other since neither one has an 

interlock 

output

 
 
 
 
 

 

48h-plc.doc 9/28/2009

 

RODIX INC. 

FEEDER CUBE

 

FC-40 

Plus Series

Plus Series

Plus Series

Plus Series

    

OIL RESISTANT 

ADJUSTMENTS AND 

SET UP 