background image

 

 

File No. E183233 

 

RODIX INCORPORATED 

TOLL FREE (800) 562-1868, FAX (815) 316-4701 

E-mail [email protected] 

rodix.com

 

 

 

 
 
 
 
 

 

FEEDER CUBE ® 

 

 

VF-3-3, P/N 121-200-0762 

 

 

CFR vibration sensor P/N 123-215 is optional 

 

 

GENERAL PURPOSE MODEL 

 

 

IMPORTANT:  APPLICATION NOTE   

 

 

 

  

              

 

 

  

Input: 85 - 264 VAC, 50/60 HZ. 
Triple Unit Fuse Sizes:  Unit A 5A, Unit B 5A, Unit C 5A 
Output: 0 - 120/240 VAC 
Maximum output voltage matches input voltage 

 

 

Output Frequency: 5 - 180Hz 

 

 

Rated Output Current each unit:  3 Amps at 120V or 2 Amps at 240V 

 

 
 

 

Model Information for each unit:  The Autotune Series of Variable Frequency Feeder Cubes® generates an output frequency 
for feeding that is independent from the power line frequency.  An optional vibration sensor, P/N 123-215, can be used to 
maintain the vibratory feeder at a constant feed rate.  The start/stop operation of the output can be controlled with an optional 
parts sensor.  For more information on this control, refer to the enclosed Adjustments and Set Up pages.  Unit A is interlocked 
(subordinate) to the operation of Unit B so that Unit A operates only when Unit B is feeding parts.  The interlock can be 
reconfigured.  The Unit C operation is independent of the other units.   

 

 

 
 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

© 2009, 2020 RODIX 

INC

 

 

 

 

 

 

 

11/20/2020

  Page 1

Содержание 121-200-0762

Страница 1: ...for each unit The Autotune Series of Variable Frequency Feeder Cubes generates an output frequency for feeding that is independent from the power line frequency An optional vibration sensor P N 123 2...

Страница 2: ...RODIX INC rodix com Toll Free 800 562 1868 FAX 815 316 4701 Email custserve rodix com VF 3 3 cover docx 10 3 2020 Page 2 RODIX INC FEEDER CUBE VF Series Wiring Diagram...

Страница 3: ...ngs 2 Enter Restores User Settings 2 Restore Settings 3 Enter Restores User Settings 3 Save Settings 1 Enter Saves User Settings 1 Save Settings 2 Enter Saves User Settings 2 Save Settings 3 Enter Sav...

Страница 4: ...C installations to bypass the phase 2 fuse L2 To bypass remove the wire connecting TB1 L2 to the L2 fuse holder Remove the terminal end of the wire connecting the L2 fuse to the power switch and conne...

Страница 5: ...r setting is displayed in the following manner A 50 0 8 Limiting the Maximum Output of Control The Max Amplitude setting can be adjusted to keep a vibratory feeder from hammering or vibrating excessiv...

Страница 6: ...djust the frequency down by 2 or 3Hz so that the feeder becomes slightly over tuned B Auto Scan scans to locate the bowl s resonate frequency Once auto tracking has found the resonate frequency it can...

Страница 7: ...nown setting Once a feed system has been set up properly the setting should be manually saved into the Save Settings1 memory If an operator disturbs the settings the Restore Settings1 feature can rest...

Страница 8: ...ies Control 1 Add a wire from term TB2 1 of the VF master control to TB2 11 of the subordinate control 2 Add a wire from TB2 2 of the VF master control to TB2 12 of the subordinate control 3 Move the...

Страница 9: ...peration Note It takes 72 hours for the adhesive to fully cure at 70 F Alternatively 8 or M4 screws can be used to mount the sensor to the feeder The mounting holes are 1 375 3 49cm apart D ROUTE THE...

Страница 10: ...f a nearby noise source Solutions for Electrical Noise 1 Use shielded wires for all I O Input Output signals The I O signals may include 4 20mA input Run input Sensor input 0 5VDC input Interlock inpu...

Отзывы: