34
MIDI STOP CHANGES
When sequencing or controlling another Rodgers console from the Theatre 360, stop
selections are normally transmitted and received using MIDI System Exclusive messages.
This allows the stops selected during sequencing to play back accurately.
If desired, the organ stops may be controlled using MIDI Program Changes rather than
System Exclusive messages. These Program Changes will control the organ pistons rather
than the individual stops. The System Exclusive method normally offers the optimum control
over registration, since it does not require the organ pistons to be set up beforehand. The use
of piston Program Changes for stop control is most useful when controlling a Rodgers organ
from a remote MIDI keyboard or when controlling a second Rodgers console other than a
Theatre 360 via MIDI.
The MIDI Stop Change menu item allows the organist to control the transmission and
reception of System Exclusive (SysEx) Stop Control messages and Piston Program Change
messages. Settings in this menu are saved when the organ is turned off.
Note: Piston Program Change messages are transmitted and received on the organ
Master Channels and should not be confused with the Program Change messages used to
select sounds from MIDI coupler pistons.
SELECTING MIDI STOP CHANGE SETTINGS:
1. Hold the SET piston, then turn the Select Knob clockwise (right) to “MIDI STOP
CHANGE”.
2. Turn the Select Knob to choose “RCV” or “SEND”.
3. Rotate the Alpha Dial to select the following options.
The Receive Field (“RCV”) has four positions:
OFF
Console ignores both SysEx and Program Changes
STP
Console receives only SysEx messages
PST
Console receives only Piston Program Changes
S&P
Console receives both SysEx and Program Changes
The Send Field (“SEND”) has the same four positions:
OFF
Console does not send either SysEx or Program Changes
STP
Console sends only SysEx messages
PST
Console sends only Piston Program Changes
S&P
Console sends both SysEx and Program Changes
Program Changes 1-12 on any Master Channel will activate the organ General Pistons of
like number. Program Change 20 on any Master Channel will activate the organ’s General
Cancel piston. Program Changes 21-26 on any Master Channel will activate the Divisional
Pistons for the division corresponding to that Master Channel.