background image

 

  

5

       

 

 

 

 

 

 

 

    

ROCPOWER

SMARTOWER

 

user

 

manual

 

CHAPTER

 

1

 

Front Panel Explanations 

 
 

1.

 

Utility

 

LED

   

 

2.

 

Fault

 

LED

   

 

3.

 

On

 

Switch

   

4.

 

Off

 

Switch

   

5.

 

Battery

 

Replacement

 

LED

   

6.

 

Battery

 

Backup

 

LED

   

 

7.

 

Screw

 

for

 

Easy

 

Swappable

 

Battery

 

Cover

  

8.

 

Battery

 

Low

 

 

9.

 

Bypass

 

 

10.

 

Utility

 

Low,

 

UPS

 

Boost

 

 

11.

 

Utility

 

High,

 

UPS

 

Buck

 

 

12.

 

UPS

 

Output

 

Indicator

 

 

13.

 

Polarity

 

Error

 

or

 

Ground

 

Fault

 

 

14.

 

Overload

 

 

15.

 

Load/Battery

 

Level

 

(%)

 

 

16.

 

Load/Battery

 

Level

 

Indication

  

Control

 

Button

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание 000 VA

Страница 1: ...power your future SMARTOWER UPS User Manual 1 000 VA 1 500 VA 2 000 VA 2 200 VA 3 000 VA...

Страница 2: ...APTER 3 8 Setup 8 IMPORTANT NOTICE 8 Connect the loads 8 Connect Computer Interface Port 8 Connect Network Surge protection 9 UPS Start Up 9 DIP Switch Setting 10 Indicators and Alarms 11 CHAPTER 4 12...

Страница 3: ...thorized technician shall void the warranty To eliminate overheating of the UPS keep all ventilation openings free from obstruction and do not store anything on top of the UPS Keep the UPS 8 inches 20...

Страница 4: ...urrent CAUTION Keep children away from this product CAUTION HEALTH CARE THE UPS IS NOT TO BE USED IN PATIENT CARE APPLICATIONS The Rocpower product you purchased was not designed for direct or indirec...

Страница 5: ...f Switch 5 Battery Replacement LED 6 Battery Backup LED 7 Screw for Easy Swappable Battery Cover 8 Battery Low 9 Bypass 10 Utility Low UPS Boost 11 Utility High UPS Buck 12 UPS Output Indicator 13 Pol...

Страница 6: ...R user manual Rear Panel Explanations 1 RJ45 Port 2 DIP Switch 3 USB Communication Port 4 RS232 Communication Port 5 Output Breaker 6 Outlet 7 Rating Label 8 Input Fuse 9 Input Power Cord Inlet Europe...

Страница 7: ...eries Please follow the instructions below 1 Keep at least 20 cm 8 inches clearance from the rear panel of the battery bank to the wall or other obstructions 2 Do not block the air flow to the ventila...

Страница 8: ...S as a master ON OFF switch ensure that all of the loads are switched ON These UPS outlets provide battery power and surge protection to the equipment when the utility voltage is outside acceptable li...

Страница 9: ...n release the ON switch 3 The Backup Mode LED Amber lights up and the UPS performs a self test If the utility is normal the UPS will run under Utility Mode Green LED after the self test is completed I...

Страница 10: ...equency of the UPS may be reset by the DIP Switch on the rear panel of the UPS The following charts show the DIP switch settings FUNCTION VOLTAGE 220V VOLTAGE 230V VOLTAGE 240V 3 1 2 N A FUNCTION VOLT...

Страница 11: ...eady with alarm Output Load is supplied by the battery Blinking every 5 seconds no alarm Standby for the utility to recover and restart the UPS Every 2 seconds before battery Low and every 1 second be...

Страница 12: ...put if the utility recovers within 24 hours after battery cutoff The Backup LED will flash every five 5 seconds during cutoff The UPS will not auto restart if the utility doesn t recover within 24 hou...

Страница 13: ...r at least 8 10 hours After recharging if the Red LED remains unchanged replace the old battery by unscrewing the Easy Swappable Battery cover Then push the ON switch to disable the Red LED Follow the...

Страница 14: ...Limited Warranty However warranty service availability and response times may vary from country to country and may also be subject to registration requirements in the country of purchase Rocstor warra...

Страница 15: ...part of the product is repaired or replaced during the Limited Warranty period Rocstor does not warrant that the operation of this product will be uninterrupted or error free Rocstor is not responsib...

Страница 16: ...Rocstor makes no representation or warranty as to the suitability or fitness of these products for any specific application Limitation of Damages Liability IF YOUR ROCSTOR BRANDED HARDWARE PRODUCT FA...

Страница 17: ...ftware or third party hardware products Options and Software The Limited Warranty terms and conditions for Rocstor options are as indicated in the Limited Warranty applicable to Rocstor options ROCSTO...

Страница 18: ...imited warranty covers repair or replacement of defective equipment at the discretion of Rocstor Repair will be from the nearest authorized service center Replacement parts and warranty labor will be...

Страница 19: ...Pacific Standard Time Customers in the United States and Canada can call toll free 888 877 8777 all others must call 818 449 2000 When calling for support please have the product s serial number and s...

Страница 20: ...Sun Sun Microsystems are trademarks or registered trademarks of Sun Microsystems Inc in the U S and other countries UNIX is a registered trademark of The Open Group Digital Equipment is trademarks of...

Страница 21: ...goal is to help our U S A and Canadian customers find a storage solution that best serves their needs We will help you determine your best purchasing options For more information please contact the ap...

Страница 22: ...22 ROCPOWER SMARTOWER user manual Notes...

Страница 23: ...23 ROCPOWER SMARTOWER user manual Notes...

Страница 24: ...24 ROCPOWER SMARTOWER user manual www ROCPOWER com 192321362022001...