Programming

For a normal usage no specifi c programming is required. But changes and functional 
details can be changes this way. 

The programming is done using the ECII FLEX emergency phone dial pad, a standard 
DTMF phone or by SMS. Following can be programmed:
• 

Idle state telephone line voltage;

• 

End-of-dial time out;

• 

Country identifi cation (international access and country code);

• 

Roaming service;

• 

Telephone number for SMS notifi cations;

• 

Administrator telephone number;

• 

Password programming;

• 

Battery test;

• 

Speech channel receiving level;

• 

Speech channel transmitting level.

 

PLEASE NOTE!
During programming the time between the dial of two digits should be not 
longer then 10 seconds. After 10 seconds without digits input you will hear a 
warning tone, after this you must hang up and terminate the programming 
session.

After each programming you will hear an acknowledge tone if the program-
ming was correct or an error tone if it was wrong. In any case a dial tone will 
follow and you can proceed with the programming or dial a telephone number.

The programming can be done also if the devices is not logged on with the 
GSM network. In this case after every acknowledge or error tone a missing 
GSM network tone will follow. Now you can proceed with the programming or 
hang up.

Idle state telephone line voltage

With this programming the idle state voltage on the telephone line which is applied 
on the RJ11 plug and the TEL screw connectors can be changed to mach the require-
ment of the connected devices. As default the line voltage is 52 VDC. To change this 
value:

DTMF

**61* 

<X> 

#

SMS

RO-IG5*

<Password (default "0")>

#61*

<X>

#

Where <X> can have the value 

for 36 VDC line voltage and 

for 52 VDC line 

voltage.

Example DTMF 

(36 VDC line voltage)

Содержание GSM500.GC

Страница 1: ...User guide GSM500 GC Issue 1 00 Page 1 USER GUIDE GSM500 GC GSM500 GC R GSM500 GC NP Adapter for the connection of analogue telephones to the GSM network ...

Страница 2: ...User guide GSM500 GC Issue 1 00 Page 2 ...

Страница 3: ...out 12 Country identification international access and country code 12 Roaming service 13 Telephone number for SMS notifications 14 Administrator telephone number 15 Password programming 15 Battery test 16 Speech channel receiving level 17 Speech channel transmitting level 17 Reset to factory default 18 Restart 18 Read the actual GSM network signal level 18 Read the actual battery status 19 Optical ...

Страница 4: ...ates the normal dial tone as used in the specific country The level of the received GSM network signal is showed any time with the green LED A new random generated PIN code is programmed the first time the device will be activated to ensure that the SIM is locked for no other use The device has an integrated emergency power supply using NiMH batteries Those are tested every two weeks If an error wil...

Страница 5: ...l level LED indicator for device status LED indicator for line status LED indicator for power supply status Automatic device reset if GSM signal is lost for a longer time Programmable end of dial waiting time Immediate end of dial using digit Programmable administrator telephone number Programmable password Programmable min power failure standby time ...

Страница 6: ...tatus white power supply status blue F RJ11 plug for the connection of an analogue telephone device or PBX trunk FXS G Plug for the external 230 VAC power supply unit H Screw connector for of an analogue telephone device or PBX trunk in parallel to the RJ11 plug I Screw connector for external 12 VDC power as alternative to the power supply unit L Contact output relay only GSM500 GC R M Connector f...

Страница 7: ...away from magnetic media like discs tapes and similar The use of the device near to electrical of electronical devices like radio TV phone sand PC may generate disturbances Radio disturbances As any other wireless device the GSM500 GC may be disturbed by radio waves Use in a car Do not use the device while driving If you plan to use the device in a car please ensure that all installed device are p...

Страница 8: ...e GSM500 GC in contact with human body Do not touch the antenna during opertation if not specifically required Use only original and approved spare parts SIM card installation For the installation of the SIM card be sure that the devices is SWITCHED OFF The SIM card has to be placed into the specific slot The card should have the PIN code disabled If a PIN code is required then you have to program i...

Страница 9: ...e device is designed for statical installation and external power supply with 230 VAC If required also a 12 VDC power voltage can be used The device has an inter nal NiMH battery for emergency power supply if external power is missing The external power supply and battery status is show by the blue LED see also LED indicators PLEASE NOTE While you are handling with the 230 VAC power be aware to fu...

Страница 10: ...ill dein stalled or fail the device will rise an appropiate alarm A battery error is also showed by the blue LED Furhermore this status is also indicated by a special dial tone Every 30 seconds the device will check if the battery is connected or not Also the batte ry capacity is tested by a discharging procedure The first time this procedure will take place 15 days after first activation During the...

Страница 11: ... after this you must hang up and terminate the programming session After each programming you will hear an acknowledge tone if the program ming was correct or an error tone if it was wrong In any case a dial tone will follow and you can proceed with the programming or dial a telephone number The programming can be done also if the devices is not logged on with the GSM network In this case after ev...

Страница 12: ...eout 10 seconds RO IG5 0 8 0 Country identification international access and country code This programming will define the country where the GSM500 has been installed This will activate specific values for that country like the call progress tones and the suppression of the international code for national caller on the CLIP International access code The international access code is the first part of t...

Страница 13: ...XXX is the MCC Mobile Country Code and YYY the MNC Mobile Net SMS RO IG5 Password default 0 08 XXXXX Where XXXXX is the value of the local international access code with max 5 digits Country code The country code is the second part of the interantional country code of your coun try In example the country code for Germany is 49 and the complete international country code is 0049 As default this cod...

Страница 14: ...TMF only provider BT UK 5 0 23476 Example SMS only provider BT UK RO IG5 0 5 0 23476 This programming enables you to define the telephone number where the notifica tion SMS are to be send to i e answer to the SMS status interrogation for battery and network and or the SMS alarms for battery failure empty battery and power failure As default no value is set here To change this value DTMF 40 telephone...

Страница 15: ...5 Password default 0 18 telephone number telephone num ber Where telephone number is the required telephone number and his repetition as acknowledge Please note The telephone number of the administrator MUST be complete with the inter national country code i e for Germany 0049 To delete the telephone number DTMF 18 SMS RO IG5 Password default 0 18 To delete the telephone number DTMF 40 SMS RO IG5 ...

Страница 16: ...tand by and up to 1 hour in active status As default the battery test is activated to deactivate it DTMF 51 SMS RO IG5 Password defaul 0 51 To reactivate this feature DTMF 50 SMS RO IG5 Password deafult 0 50 A further programming is the minimum stand by time the battery must support If during the battery test the device will recognize that the battery capacity is below this minimum required time a...

Страница 17: ...lease note If you activate the device the first time without conneting the battery you will get a battery alarm after 30 seconds After connecting the battery it can take up to 15 days before the battery alarm will be set back Speech channel receiving level You can change the speech receiving level if required As default it is set to 2dB To change this value DTMF 11 X SMS RO IG5 Password default 0 1...

Страница 18: ...ollo wing programming DTMFV 98 SMS RO IG5 Password default 0 98 Read the actual GSM network signal level Further to the LED indicator you can anytime read out the actual GSM networking signal using this programming DTMF 30 You will get the following tone feedback SMS RO IG5 Password default 0 10 X Where X can have the following values 1 2 3 4 5 6 7 2dB 0dB 4dB 6dB 9dB 11dB 12dB Please note This va...

Страница 19: ...get the following feedback as SMS RO IG5 Password default 0 30 X Where X can have the following values 0 No GSM signall 1 Poor signal 25 2 Average signal 50 3 Good signal 75 4 Very good signal 100 Read the actual battery status Further to the LED indicator you can anytime read out the actual battery status using this programming DTMF 91 You will get the following feedback as SMS Battery X ...

Страница 20: ...No battery installed 1 Poor 25 ca 2h standyby 2 Average 50 ca 4h standby 3 Good 75 ca 6h standby 4 Very good 100 ca 8h standby Optical indicators Green LED for GSM signal strenght No GSM signal Poor signal 25 Average signal 50 Good signal 75 Very good signal 100 Red LED for device status Device is trying to register into the GSM network Device is registred a ready to use Device is busy ...

Страница 21: ...ice using a ring voltage Getting off hook the call will be answered Outgoing call 1 Size the line going off hook or sizing the trunk of the connected PBX 2 You will get dial tone from the GSM500 or special dial tone if the battery is bro ken or the device is using another provider roaming tone 3 Dial a telephone number 4 If the called party is busy or the GSM network has problems i e overload you ...

Страница 22: ...e PIN code or did you have programmed the PIN code 0000 GSM500 gateway is not initialising the green LED is off Check the following 1 Do you have network signal recepiton The PBX or emergency phone connected to the GSM500 are not able to dial external numbers Check the following 1 Does your PBX or emergency phone have a dial tone detection 2 Have you activated the appropiate dial tone programming ...

Страница 23: ... DTMF Programming using DTMF or SMS Dimensions HxLxD 140 x 96 x 28 mm Weight 220 g with battery Operational temperature 20 to 50 C Humidity 30 to 90 relative humidity degree w o condens ing Casing ABS Protection degree IP20 GSM engine Dual band 900 1800 Mhz external 50 Ohm an tenna with SMA connector Specification reference EN60950 1 EN50385 EN301489 1 EN301489 7 EN12015 EN12016 EN301511 Type appro...

Страница 24: ...teme GmbH Lessing Str 20 63110 Rodgau Deutschland Tel 49 0 6106 6600 0 Fax 49 0 6106 6600 66 E Mail info rocom gmbh de http www rocom gmbh de 2015 ROCOM GmbH We do not take any responsabilty for changes and errors in the present documentation Printed in Germany 29 6900 0190 Ver 1 00 ...

Отзывы: