Installation Instructions

Original Instructions

VersaView 6300B Box PCs and 6300T Box Thin Clients

Bulletin Numbers 6300B-BMA

x

, 6300B-BMB

x

, 6300B-BMF

x

, 6300B-DRF

x

, 6300T-BA

x

1

Summary of Changes

This publication contains the following new or updated information. This list includes substantive updates only and is not intended to reflect all changes. Translated versions are not 
always available for each revision.

Environment and Enclosure Information

UL/cUL Mark Compliance

Equipment with the UL/cUL mark complies with the requirements of UL 61010-1, UL 61010-2-201, CSA C22.2 No. 61010-1, and CSA C22.2 No. 61010-2-201. A copy of the certificate of 
compliance is available at 

rok.auto/certifications

.

European Union Directive Compliance

This equipment meets the European Union Directive requirements when installed within the European Union or EEA regions and have the CE marking. A copy of the declaration of the 
conformity is available at 

rok.auto/certifications

.

Topic

Page

Removed ‘book mount’ from publication title and wherever used in publication.

Throughout

Added the Important table to Required Tools and Hardware for Installation section.

2

Changed from 2.5 mm Phillips screwdriver to #2 Phillips screwdriver in Required Tools and Hardware for Installation section.

2

Expanded dimensional drawings into Figure 1 and added the following:

• Dimensional drawings and callouts for the 6300B-BMF

x

 and 6300B-DRF

x

 box PCs

• Any missing English unit equivalents for the 6300B-BMA

x

 box PCs, 6300T-BA

x

1 thin clients, and 6300B-BMB

x

 Box PCs

• Overall depth dimension for the 6300B-BMB

x

 Box PCs

• Revised the callout title from ‘6300B-BMA

x

 and 6300T-BA

x

1 Box PCs’ to ‘6300B-BMA

x

 Box PCs and 6300T-BA

x

1 Box Thin Clients’

2

Added the Install a Box PC With the DIN Rail Bracket section.

2

Added the following to the Connect Peripherals section:

• The picture for 6300B-BMF

x

 and 6300B-DRF

x

 models

• The digital input/output (I/O) item to the picture and table

• The USB cable length stipulation

4

Changed the heading from ‘Connect DC Power’ to ‘Connect DC Power Wiring.’

4

Added the subheading ‘For 6300B-BMA

x

 and 6300B-BMB

x

 Box PCs, and 6300T-BA

x

1 Box Thin Clients’ to the Install the DC Connector Assembly section.

5

Added the For 6300B-BMF

x

 and 6300B-DRF

x

 Box PCs subsection.

6

Added the Connect DC Power section.

6

Expanded the Table 1 title to include 6300B-BMF

x

 and 6300B-DRF

x

 Box PCs.

6

ATTENTION: 

This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in 

IEC 60664-1), at altitudes up to 2000 m (6561 ft) without derating.

This equipment is considered Group 1, Class A industrial equipment according to IEC/EN 61326-1. Without appropriate precautions, there can be potential 

difficulties with electromagnetic compatibility in other environments due to conducted as well as radiated disturbance.

This equipment is considered open equipment, which means it must be mounted in an enclosure where the equipment can be operated from the front panel.

The enclosure in which this equipment is installed must be accessed only with a key or tool, and only by trained and authorized personnel.

In addition to this publication, see the following:

• Industrial Automation Wiring and Grounding Guidelines, publication 

1770-4.1

, for more installation requirements

• UL 50, CSA C22.2 No. 94.1, and IEC 60529, as applicable, for explanations of the degrees of protection provided by enclosures

ATTENTION: 

This equipment is intended to operate in an industrial or control room environment, which uses some form of power isolation from the public 

low-voltage mains. Some computer configurations cannot comply with the EN 61000-3-2 Harmonic Emissions standard as specified by the EMC Directive of 

the European Union.
All I/O cables must be used only indoors.

Содержание Allen-Bradley VersaView 6300B

Страница 1: ...ing to the Connect Peripherals section The picture for 6300B BMFx and 6300B DRFx models The digital input output I O item to the picture and table The USB cable length stipulation 4 Changed the heading from Connect DC Power to Connect DC Power Wiring 4 Added the subheading For 6300B BMAx and 6300B BMBx Box PCs and 6300T BAx1 Box Thin Clients to the Install the DC Connector Assembly section 5 Added...

Страница 2: ... at the bottom as shown in Figure 1 on page 3 Mount the box PC or box thin client so there is at least 20 mm 0 8 in of clearance on each side for the circulation necessary for cooling Required Tools and Hardware for Installation The following tools are needed for the mounting bracket installations A drill and 4 mm drill bit 2 Phillips screwdriver Four M4x20 stainless steel screws customer supplied...

Страница 3: ...0 75 230 9 06 19 0 75 6 0 24 4 x Ø 4 1 8 25 0 98 25 0 98 100 3 97 150 5 9 5 5 0 22 100 3 97 150 5 9 256 5 10 1 268 10 6 Front View Vertical Upright Position Side View 6300B BMAx Box PCs and 6300T BAx1 Box Thin Clients 6300B BMBx Box PCs 221 8 7 6300B BMFx Box PCs 47 1 85 4 5 0 18 127 25 5 01 140 5 51 20 0 79 100 3 94 8 25 0 32 77 3 03 100 3 94 20 0 79 4 x Ø 4 5 0 18 Front View Vertical Upright Pos...

Страница 4: ...wer Wiring Follow these steps to connect the box PC or box thin client to a DC power source Install the Ground Wire 1 Turn off the main power switch or breaker 2 Remove the supplied nut eyelet terminal and washers from the ground screw 3 For earth ground fasten a 2 5 mm2 14 AWG or larger external wire to the eyelet terminal Use a ground wire with an insulation color that is approved by local inspe...

Страница 5: ...es 9 Use cutting pliers to cut the excess part of the cable tie D 10 Install the white label supplied with the kit E 11 Align and install the other connector clamp half to complete the assembly F 12 Reconnect the DC terminal block with the connector assembly to the computer chassis Torque the DC terminal block flange screws to the values in Figure 2 13 Proceed to Connect DC Power on page 6 IMPORTA...

Страница 6: ...ally starts the computer after it is plugged into a power source For VersaView 6300B box PCs with a Microsoft Windows operating system OS you must read and accept an End User Setup procedure Do not disconnect power from the system until after the Windows Setup procedure is completed If power is disconnected during this procedure it can result in a corrupted system image Table 1 LEDs and Buttons on...

Страница 7: ...ate and time 5 Watchdog LED Green The watchdog is working Red The watchdog timer has expired 6 PLC status LED 2 7 BUS status LED 2 8 Power on reset button Turns the computer on or off 9 System reset button Forces an internal reset as if power was lost temporarily and then returned IMPORTANT Use this button only if there are no better options like keyboard or mouse commands System reset can cause d...

Страница 8: ...on its website at rok auto pec Your comments help us serve your documentation needs better If you have any suggestions on how to improve our content complete the form at rok auto docfeedback For technical support visit rok auto support Rockwell Otomasyon Ticaret A Ş Kar Plaza İş Merkezi E Blok Kat 6 34752 İçerenkÖy İstanbul Tel 90 216 5698400 EEE YÖnetmeliğine Uygundur This computer contains a sea...

Отзывы: