Publication 440N-IN008B-EN-P — December 2014 — 10000979555 Ver 00
PN-243696
Supersedes Publication 440N-IN0008A-EN-P — May 2012
Copyright © 2014 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
Rockwell Automation maintains current product environmental information on its website at
http//www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page
List of Recommended Safety Control Interfaces
GSR DI, GSR DIS, GSR SI, CR30, MSR126, MSR127, MSR131, MSR138, MSR211, MSR221, MSR121, MSR320, SmartGuard™, 1791DS/ES
CompactBlock™ Guard Safety I/O, 1732DS/ES ArmorBlock Guard Safety I/O. Relay must have OSSD (light curtain) inputs.
Maintenance
Monthly
Check the correct operation of the switching circuit. Also check for signs of abuse or tampering. Inspect the switch casing for damage.
Repair
If there is any malfunction or damage, no attempts at repair should be made. The unit should be replaced before machine operation is
allowed.
Declaration of Conformity
This is to declare that the products shown in this document conform with the Essential Health and Safety Requirements (EHSRs) of the
European Machinery Directive. These products also conform to EN 60947-5-3, EN ISO 14119, and have Third Party Approval.
For a comprehensive certificate please visit: www.ab.com/safety.
Check the machine is
isolated and stopped
whenever the interlocked
guard door is open.
IMPORTANT:
After
installation and
commissioning, the
actuator, switch and switch
lid fixing screws should be
coated with tamper evident
varnish or similar compound.
Allen-Bradley, CompactBlock, Rockwell Software, and SensaGuard are trademarks of Rockwell Automation, Inc.