List of Recommended Safety Control Interfaces

GSR DI, GSR DIS, GSR SI, CR30, MSR126, MSR127, MSR131, MSR138, MSR211, MSR221, MSR121, MSR320, SmartGuard™, 1791DS/ES 
CompactBlock™ Guard Safety I/O, 1732DS/ES ArmorBlock Guard Safety I/O. Relay must have OSSD (light curtain) inputs.

Maintenance

Monthly

Check the correct operation of the switching circuit. Also check for signs of abuse or tampering. Inspect the switch casing for damage.

Repair

If there is any malfunction or damage, no attempts at repair should be made. The unit should be replaced before machine operation is 
allowed.

Declaration of Conformity

This is to declare that the products shown in this document conform with the Essential Health and Safety Requirements (EHSRs) of the 
European Machinery Directive. These products also conform to EN 60947-5-3, EN ISO 14119, and have Third Party Approval.

For a comprehensive certificate please visit: www.ab.com/safety.

 

Check the machine is 
isolated and stopped 
whenever the interlocked 
guard door is open.

IMPORTANT:

 After

installation and 
commissioning, the 
actuator, switch and switch 
lid fixing screws should be 
coated with tamper evident 
varnish or similar compound.

Allen-Bradley, CompactBlock, Rockwell Software, and SensaGuard are trademarks of Rockwell Automation, Inc.

Содержание SensaGuard 440N-Z21SS2 Series

Страница 1: ...el campo de b squeda PORTUGUESE Esta folha de instru es est dispon vel em v rias l nguas em www rockwellautomation com literature Seleccione a l ngua de publica o e entre com SensaGuard no espa o de b...

Страница 2: ...h other Mount the switch and actuator to removable guard door or gate Keep the switch and actuator within the sensing range shown in the sensing misalignment curve Nut Torque Specification Switch Actu...

Страница 3: ...TANC E when the actuator approaches the sensor in the x direction or from above z direction and is misaligned in the y direction Sensor Actuator Misalignment mm Assured Make 15 mm Assured OFF 35 mm x...

Страница 4: ...mber Signal 1 24V 2 OSSD 1 3 0V 4 OSSD 2 5 Aux Device Output LED State Status Troubleshooting Off Not Powered NA Red Not Safe OSSD not active NA Green Safe OSSD active NA Green Flash Power up test or...

Страница 5: ...Flashing to indicate Series inputs are not 24V Actuator 5 is in sensing range Switch 5 is functioning properly Series inputs are 0V OSSDs are de energized to 0V Green LED is Flashing to indicate Seri...

Страница 6: ...y Pink Yellow Red Brown SensaGuard Unit 1 SensaGuard Unit 2 SensaGuard Unit 3 GuardShield Blue Gray Pink Yellow Red Brown Blue Gray Pink Yellow Red Brown Blue Gray Pink Brown A1 S11 S52 S12 13 23 33 4...

Страница 7: ...ite Black SensaGuard Integrated Latch Reset Gate Open Grey IMPORTANT 889D F8AB A1 S11 S21 S12 S22 S32 L11 Y32 L12 13 14 S42 23 24 S34 A2 DI 440R D22R2 0 1 2 3 4 5 6 7 8 LOGIC K1 K2 K1 K2 S11 S12 S21 S...

Страница 8: ...witching circuit Also check for signs of abuse or tampering Inspect the switch casing for damage Repair If there is any malfunction or damage no attempts at repair should be made The unit should be re...

Отзывы: