2
Protection
Dimensions [mm (in.)]
Mode of Operation
Status indicators:
•
“Status/Diag” LED illuminates green:
Door/guard closed,
safety outputs active.
•
“Status/Diag” LED illuminates red:
Door/guard open,
safety outputs off.
•
“Status/Diag” LED flashes red:
Unit failure. See Diagnostic
section on page 4.
•
“Status/Diag” LED flashes green:
Safety inputs off.
•
“Status/Diag” LED flashes amber:
Sensor is approaching
max. sensing distance. (-N and -N9 models only)
Mounting Information
Use non-removable screws, bolts, or nuts to mount the switch and
actuator. Do not over torque the mounting hardware.
Position the switch and actuator so they are aligned with each
other.
Mount the switch and actuator to removable guard, door, or gate.
Keep the switch and actuator within the sensing range shown in
the sensing/misalignment curve.
Nut Torque Specification
Switch/Actuator: 2.26 N•m (20 in•lb)
Short-circuit Incorporated
Current Limitation
Incorporated
Overload
Incorporated
False Pulse
Incorporated
Transient Noise
Incorporated
Reverse Polarity
Incorporated
Overvoltage
Incorporated
Thermal Shutdown/Restart
Incorporated
Electrical Life
10 x 10
6
24.99
(0.984)
88.14
(3.47)
10.66
(0.42)
7.11
(0.28)
6.78
(0.267)
4.57
(0.18)
Ø5.08
(Ø0.2)
4.57
(0.18)
68.31
(2.689)
18.54
(0.73)
72.9
(2.87)
77.98
(3.07)
20.65
(0.813)
24.99
(0.984)
88.14
(3.47)
20.65
(0.813)
4.57
(0.18)
18.54
(0.73)
10.67
(0.42)
13.41
(0.528)
9.96
(0.392)
QD
CONNECTOR
VERSION
M12 x 1
¯ 9.7
(¯ 0.38)
4.57
(0.18)
Ø5.08
(Ø0.2)
4.57
(0.18)
77.98
(3.07)
62.53
(2.462)
57.96
(2.282)
82.55
(3.25)