MSR300 Safety System Manual
Rockwell Automation
MSR300 Manual.doc
Pg 72 of 85
9.2.2 MSR310 Parameters
Para-
meter
R/W Name
Size
Value
Address
1
R
Device status
2 bytes
0x0000 – 0xFFFF
0x0000
2
R
Input status 1
2 bytes
0x0000 – 0xFFFF
0x0001
3
R
Input status 2
2 bytes
0x0000 – 0xFFFF
0x0002
4
R
Configuration status EM 1
2 bytes
0x0000 – 0xFFFF
0x0003
5
R
Configuration status EM 2
2 bytes
0x0000 – 0xFFFF
0x0004
6
R
Configuration status EM 3
2 bytes
0x0000 – 0xFFFF
0x0005
7
R
Configuration status EM 4
2 bytes
0x0000 – 0xFFFF
0x0006
8
R
Configuration status EM 5
2 bytes
0x0000 – 0xFFFF
0x0007
9
R
Configuration status EM 6
2 bytes
0x0000 – 0xFFFF
0x0008
10
R
Configuration status EM 7
2 bytes
0x0000 – 0xFFFF
0x0009
11
R
Configuration status EM 8
2 bytes
0x0000 – 0xFFFF
0x000A
12
R
Configuration status EM 9
2 bytes
0x0000 – 0xFFFF
0x000B
13
R
Configuration status EM 10
2 bytes
0x0000 – 0xFFFF
0x000C
14
R
Input with error monitoring:
extension modules 1 to 8
2 bytes
0x0000 – 0xFFFF
0x000D
15
R
Input with error monitoring:
extension modules 9 to 10
2 bytes
0x0000 – 0xFFFF
0x000E
16
R
Input switch error status
2 bytes
0x0000 – 0xFFFF
0x000F
17
R
Input switch error status, other
faults, version number,
number of input modules
2 bytes
0x0000 – 0xFFFF
0x0010
18
R/W
Bus status (Baud rate)
2 bytes
0x0000 – 0x0300
0x0011
Status of device (Parameter 1: configuration and status of device)
High Byte:
Bit Function
7 + 6 00: Jumper Y40 – Y41–Y42
01: Jumper Y40 – Y41
10: Jumper Y40 – Y42
11: Y41 and Y42 open
5 Group
3
active
4 Group
2
active
3 Group
1
active
2
Group 3 ready
1
Group 2 ready
0
Group 1 ready