Rockwell Automation ControlLogix 1756-PA72 Series C Скачать руководство пользователя страница 4

4

     ControlLogix Power Supplies

Publication 1756-IN613A-EN-P - December 2008

Safety-related Programmable Electronic Systems

North American Hazardous Location Approval

ATTENTION

Personnel responsible for the application of safety-related programmable electronic 
systems (PES) shall be aware of the safety requirements in the application of the system 
and shall be trained in using the system.

The following information applies when operating 
this equipment in hazardous locations.

Informations sur l’utilisation de cet équipement en 
environnements dangereux.

Products marked "CL I, DIV 2, GP A, B, C, D" are suitable for use in 
Class I Division 2 Groups A, B, C, D, Hazardous Locations and 
nonhazardous locations only. Each product is supplied with 
markings on the rating nameplate indicating the hazardous 
location temperature code. When combining products within a 
system, the most adverse temperature code (lowest "T" number) 
may be used to help determine the overall temperature code of 
the system. Combinations of equipment in your system are subject 
to investigation by the local Authority Having Jurisdiction at the 
time of installation.

Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne conviennent 
qu'à une utilisation en environnements de Classe I Division 2 
Groupes A, B, C, D dangereux et non dangereux. Chaque produit 
est livré avec des marquages sur sa plaque d'identification qui 
indiquent le code de température pour les environnements 
dangereux. Lorsque plusieurs produits sont combinés dans un 
système, le code de température le plus défavorable (code de 
température le plus faible) peut être utilisé pour déterminer le 
code de température global du système. Les combinaisons 
d'équipements dans le système sont sujettes à inspection par les 
autorités locales qualifiées au moment de l'installation.

WARNING

EXPLOSION HAZARD -

• Do not disconnect equipment 

unless power has been removed 
or the area is known to be 
nonhazardous. Do not disconnect 
equipment unless power has 
been removed or the area is 
known to be nonhazardous. 

• Do not disconnect connections to 

this equipment unless power has 
been removed or the area is 
known to be nonhazardous. 
Secure any external connections 
that mate to this equipment by 
using screws, sliding latches, 
threaded connectors, or other 
means provided with this product.

• Substitution of components may 

impair suitability for Class I, 
Division 2.

• If this product contains batteries, 

they must only be changed in an 
area known to be nonhazardous.

AVERTISSEMENT

RISQUE D’EXPLOSION – 

•  Couper le courant ou s'assurer 

que l'environnement est classé 
non dangereux avant de 
débrancher l'équipement.

• Couper le courant ou s'assurer 

que l'environnement est classé 
non dangereux avant de 
débrancher les connecteurs. Fixer 
tous les connecteurs externes 
reliés à cet équipement à l'aide 
de vis, loquets coulissants, 
connecteurs filetés ou autres 
moyens fournis avec ce produit.

• La substitution de composants 

peut rendre cet équipement 
inadapté à une utilisation en 
environnement de Classe I, 
Division 2.

• S'assurer que l'environnement est 

classé non dangereux avant de 
changer les piles.

Содержание ControlLogix 1756-PA72 Series C

Страница 1: ...ted on the left end of the chassis where they are plugged directly into the backplane Topic Page Important User Information 2 Environment and Enclosure 3 Safety related Programmable Electronic Systems...

Страница 2: ...ation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation Inc with respect to use...

Страница 3: ...imize the spread of flame complying with a flame spread rating of 5VA V2 V1 V0 or equivalent if non metallic The interior of the enclosure must be accessible only by the use of a tool Subsequent secti...

Страница 4: ...reux Lorsque plusieurs produits sont combin s dans un syst me le code de temp rature le plus d favorable code de temp rature le plus faible peut tre utilis pour d terminer le code de temp rature globa...

Страница 5: ...potentially explosive atmospheres given in Annex II to this Directive Compliance with the Essential Health and Safety Requirements has been assured by compliance with EN 60079 15 and EN 60079 0 WARNI...

Страница 6: ...ower supply 1 Align the power supply circuit board with the card guides on the left side of the chassis 2 Guide the extended tab on the power supply circuit board into the notch of the chassis Chassis...

Страница 7: ...ControlLogix Power Supplies 7 Publication 1756 IN613A EN P December 2008 3 Slide the power supply in until it is flush with the back of the chassis 4 Fasten the power supply to the chassis 44144 44145...

Страница 8: ...und from the chassis to the system earth ground 3 Tighten the nut on the equipment protective earth ground terminal stud to a torque of 1 4 N m 12 lb in Item Description 1 Wiring terminal block 2 Prot...

Страница 9: ...ected to the system We recommend that you use a ground bus to reduce the electrical resistance at the connection For more information on grounding the wiring to the ControlLogix chassis refer to the C...

Страница 10: ...WARNING If you connect or disconnect wiring while the field side power is on an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed...

Страница 11: ...of the power supply Power Supply Connections Item Description 1 L1 High side of line power AC Power Supplies 2 L2 N Low side of line power 3 a Protective earth ground terminal 3 b Protective earth gr...

Страница 12: ...ower supplies given the power they are providing to the modules in the chassis The vertical axis of each graph shows the backplane power consumed by all of the modules in the chassis the horizontal ax...

Страница 13: ...vertical axis 3 Follow that value to the right until it intersects the line on the graph 4 Find the associated input power rating consumed by the power supply on the horizontal axis For example if th...

Страница 14: ...line power OFF 3 Loosen the screws holding the power supply to the chassis See page 7 for the location of the screws on the power supply 4 Slide the power supply out so that the rear connector is disc...

Страница 15: ...r 100VA Input power max 100VA 100 W Output power max 1 75 W 60 C 140 F Power dissipation 85 3 BTU hr Power consumption 25 W 60 C 140 F Hold up time 2 5 cycles 85V AC 50 60 Hz 6 cycles 120V AC 50 60 Hz...

Страница 16: ...ions Attribute 1756 PA72 Series C 1756 PA75 Series B Operating temperature IEC 60068 2 1 Test Ad Operating Cold IEC 60068 2 2 Test Bd Operating Dry Heat IEC 60068 2 14 Test Nb Operating Thermal Shock...

Страница 17: ...56 PA72 Series C 1756 PA75 Series B UL UL Listed Industrial Control Equipment See UL File E65584 CSA Certified Process Control Equipment See CSA File LR54689C CSA Certified Process Control Equipment f...

Страница 18: ...ut voltage nom 24V DC 48V DC 125V DC Input power max 95 W Output power max 75 W 60 C 140 F 2 Power dissipation 68 2 BTU hr Power consumption 20 W 60 C 140 F Hold up time 35 ms 18V DC 3 40 ms 24V DC 40...

Страница 19: ...due to short circuit conditions 6 Use this Conductor Category information for planning conductor routing Refer to Industrial Automation Wiring and Grounding Guidelines publication 1770 4 1 1756 PB72...

Страница 20: ...ckaged Nonoperating Damp Heat 5 95 noncondensing Vibration IEC 60068 2 6 Test Fc Operating 2 g 10 500 Hz Operating shock IEC 60068 2 27 Test Ea Unpackaged Shock 30 g Nonoperating shock IEC 60068 2 27...

Страница 21: ...variation IEC 61000 4 11 IEC 61000 4 29 60 dips for 100 ms on DC supply ports 100 dips for 50 ms on DC supply ports 20 fluctuations for 15 min on DC supply ports 5 s interruptions on DC supply ports 1...

Страница 22: ...56 PC75 Series B 1756 PH75 Series B Certifications 1 Certifications 2 1756 PC75 Series B 1756 PH75 Series B UL UL Listed Industrial Control Equipment See UL File E65584 CSA CSA Certified Process Contr...

Страница 23: ...ption 1756 A4 1756 A7 1756 AI0 1756 A13 1756 A17 ControlLogix Chassis Installation Instructions publication 1756 IN080 Provides information about installing a ControlLogix chassis and technical specif...

Страница 24: ...ou experience a problem within the first 24 hours of installation please review the information that s contained in this manual You can also contact a special Customer Support number for initial help...

Отзывы: