Chapter 2 Install the Panel PC
Mounting Requirements
Follow these requirements to mount the VersaView 6300P panel PC.
•
Choose a suitable mounting height.
•
For optimal performance, mount the computers in the vertical
(upright) position, so the I/O ports face down.
•
To help prevent
overheating and to
provide access to the
I/O ports for cable
connections, mount
the computer so there
are the following
minimum clearances:
- X and Z directions:
7 cm (2.75 in.)
- Y direction:
10 cm (3.94 in.)
Enclosure Requirements
•
The enclosure must allow sufficient space around air inlets and outlets
to provide the circulation necessary for cooling. For further
information, see
on this page. Never allow air
passages to become obstructed.
•
Hot air rises. The temperature at the top of the enclosure is often higher
than the temperature in other parts of the enclosure, especially if air is
not circulating.
Consider a user-supplied fan, heat exchanger, or air conditioner for
heat generated by other devices in the enclosure. See
for the acceptable temperature ranges for these
computers.
Prepare the Panel Cutout
Observe these guidelines to install the computer in a panel.
•
Plan the panel cutout according to the following:
- The acceptable horizontal orientation and vertical position; see the
Installation Guidelines on page 14
.
- The panel cutout dimensions needed for your computer that are
found on
•
The mounting panel material must be 2…6 mm (0.08…0.24 in.) thick.
•
For a uniform gasket seal, the roughness of the panel surface must not
exceed 120 microns (Rz 120).
•
Confirm that there is adequate space behind the panel as needed. For
specific information, see
on this page.
•
Verify that the area around the panel is clear of obstructions.
•
Remove all electrical power from the panel before you make the cutout.
IMPORTANT
The vertical position can be tilted up to 20° forward or backward
from the upright position. However, any tilt angle reduces the
maximum operating temperature by 5 °C (41 °F).
Y
Y
X
X
Z
I/O Ports Face Down
Vertical (Upright)
Position
0°
(preferred)
20°
max
20°
max
ATTENTION:
Failure to follow these guidelines can result in personal injury or
damage to the panel components.
Take precautions so any metal fragments during the panel cutout do not enter
components that are installed already in the panel.
Содержание Allen-Bradley VersaView 6300P Series
Страница 1: ...VersaView 6300P Panel PCs Catalog Number 6300P User Manual Original Instructions ...
Страница 8: ...8 Rockwell Automation Publication 6300P UM001B EN P March 2021 Preface Notes ...
Страница 12: ...12 Rockwell Automation Publication 6300P UM001B EN P March 2021 Chapter 1 About the Panel PC Notes ...
Страница 24: ...24 Rockwell Automation Publication 6300P UM001B EN P March 2021 Chapter 3 Operate the Panel PC Notes ...
Страница 42: ...42 Rockwell Automation Publication 6300P UM001B EN P March 2021 Chapter 6 Troubleshoot the System Notes ...