Access Procedures
Chapter 3
5.
Remove the three hexalobular screws that secure the resolver feedback
board to the stand-offs on the resolver interface board and carefully
remove the resolver feedback board.
IMPORTANT
The resolver feedback board is connected to the resolver interface
board below it via stacker connector pins at connectors P2 and P3. Lift
the resolver feedback board straight up during removal to avoid any
damage to the connector pins.
S15
XR
XA
XP3
XRE
XFCD
S21
S4
J1
J2
P1
S1
TB1
TB2
P4
P2
P3
P1
5
Tightening torque for
reassembly is
0.7 N
•
m (6.2 lb
•
in)