background image

Quick Start 

PanelView Plus 7 Performance 

Series B Terminals

Содержание Allen-Bradley PanelView Plus 7

Страница 1: ...Quick Start PanelViewPlus7Performance Series B Terminals...

Страница 2: ...ess Steel terminals which run on the Windows 10 IoT Core operating system The startup procedure for these terminals is different than for a Series A terminal Please follow this quick start guide for t...

Страница 3: ...ummary of Changes 4 Before You Begin 4 Power up the Terminal 4 Configure the Terminal 5 Update the Firmware 9 USB Storage Device 9 ControlFLASH Client 11 Enter a Password 18 Transfer Runtime Files mer...

Страница 4: ...e terminal Stainless steel terminals come with the following items included in the box Mounting clips for panel installation Backing plate Hygienic gasket In addition to these items make sure that you...

Страница 5: ...Yes 3 On the first calibration screen calibrate the touch screen boundaries as prompted WARNING Series B terminals are designed for use with DC power only Do not apply AC power or attempt to insert a...

Страница 6: ...libration screen calibrate the touch screen as prompted a Carefully tap and hold the center of the target for at least 1 second The target moves after you do this b Repeat as the target moves around t...

Страница 7: ...type the password in the Confirm password must match password above field 12 Tap Next The terminal displays the Network Adapters setup screen For all of the following PanelView screens if you do not h...

Страница 8: ...specify your own DNS information turn this field Off by tapping the button indicator and sliding it to the left The following fields become active so that you can type your information into them Pref...

Страница 9: ...o pcdc 2 On the home page click Available Versions 3 Click the Select a Product link and in the Select a Product dialog box type PanelView Plus 7 Performance in the search field and then click the Sea...

Страница 10: ...USB Storage and wait for the firmware update to complete Before the update starts the terminal displays the warning message shown in the following graphic As the message states do not remove the USB s...

Страница 11: ...een 12 Continue with Enter a Password on page 18 ControlFLASH Client The following ControlFLASH clients are available to update the firmware ControlFLASH Plus ControlFLASH Before you can use ControlFL...

Страница 12: ...RockwellAutomation Firmware Kits 8 On the PanelView terminal under System Firmware tap the Start Update Utility button Using ControlFLASH Plus For details about how to install ControlFLASH Plus softwa...

Страница 13: ...cation 2711P QS002B EN P April 2022 13 Getting Started 3 Click Next 4 Confirm that the information is correct and then click Flash A series of status changes occur on the ControlFLASH Plus screen and...

Страница 14: ...lFLASH Plus screen the Status field displays the Transmitting update status On the PanelView terminal the status changes to CONNECTED transferring updates Once the firmware file transmission is comple...

Страница 15: ...rifying and preparing updates The PanelView terminal reboots and on the ControlFLASH Plus screen the Flash Results dialog box displays a Succeeded message 5 Click Close and then click Done When the fi...

Страница 16: ...s B terminal follow these steps 1 Click Start Programs FLASH Programming Tools ControlFLASH 2 Make sure that you know the required information in the Welcome dialog box then click Next 3 Select the ca...

Страница 17: ...ell Automation Publication 2711P QS002B EN P April 2022 17 Getting Started 5 Select the firmware revision to install and click Next 6 Read the Danger information in the Summary dialog then click Finis...

Страница 18: ...n see the ControlFLASH User Manual publication 1756 UM105 9 Close the ControlFLASH software 10 Continue with Enter a Password on page 18 Enter a Password After the PanelView terminal is updated with t...

Страница 19: ...er to the challenge question The response needs to be a minimum of 6 characters 5 Tap OK The terminal displays the FactoryTalk View ME Station startup screen If you do not have a keyboard or mouse con...

Страница 20: ...Transfer Utility via ethernet Removable storage device USB drive or SD card Transfer Utility To transfer runtime files mer by using the Transfer utility complete the following steps 1 From the Factory...

Страница 21: ...y using a removable storage device complete the following steps 1 Insert the removable storage device in the appropriate port on your work station 2 On your work station browse to the following locati...

Страница 22: ...or No 13 Continue with Install the Terminal on page 22 Install the Terminal After you complete all of the previous procedures you are ready to install your PanelView Plus 7 Performance Series B termi...

Страница 23: ...12 101 for the PanelView Plus 7 Performance Series B terminals PanelView Plus 7 Performance Terminals User Manual publication 2711P UM008 Describes how to install configure operate and troubleshoot t...

Страница 24: ...rok auto knowledgebase Local Technical Support Phone Numbers Locate the telephone number for your country rok auto phonesupport Literature Library Find installation instructions manuals brochures and...