10
Rockwell Automation Publication TLP-IN001A-EN-P - October 2019
Kinetix TLP Servo Motors with 046…235 mm Frame Size
Load Force Ratings
Motors are capable of operating with a sustained shaft load. The location and direction of radial and axial load forces are shown in the figure, and
maximum load rating values are in the tables.
Load Forces on Shaft
The following tables represent 40,000-hour L
10
bearing fatigue life at various loads and speeds. This 40,000-hour bearing life does not account for
possible application-specific life reduction, such as bearing grease contamination from external sources.
Radial Load Force Ratings (maximum) for Non-brake Motors
Motor
Cat. No.
(1)
(1)
1.0 kgf = 2.2 lbf or 9.8 N.
Speed, max
rpm
RPM
500
kgf
750
kgf
1000
kgf
1125
kgf
1250
kgf
1500
kgf
2000
kgf
2250
kgf
2500
kgf
3000
kgf
3375
kgf
3750
kgf
4500
kgf
5000
kgf
6000
kgf
TLP-A046-005-D
xxx
2
x
6000
–
–
–
–
–
8.8
–
–
–
7.0
–
–
6.1
–
5.6
TLP-A046-010-D
xxx
2
x
6000
–
–
–
–
–
9.7
–
–
–
7.7
–
–
6.8
–
6.1
TLP-A070-020-D
xxx
2
x
6000
–
–
–
–
–
22.4
–
–
–
17.8
–
–
15.5
–
14.1
TLP-A070-040-D
xxx
2
x
6000
–
–
–
–
–
25
–
–
–
19.9
–
–
17.4
–
15.8
TLP-A090-075-D
xxx
2
x
6000
–
–
–
–
–
35.6
–
–
–
28.2
–
–
24.7
–
22.4
TLP-A100-100-D
xxx
2
x
3000
–
61.8
–
–
–
49.0
–
42.8
–
38.9
–
–
–
–
–
TLP-A115-100-D
xxx
2
x
5000
–
–
–
–
52.9
–
–
–
42
–
–
36.7
–
33.3
–
TLP-A115-200-D
xxx
2
x
5000
–
–
–
–
58.1
–
–
–
46.1
–
–
10.3
–
36.6
–
TLP-A145-050-D
xxx
2
x
3000
–
106.8
–
–
–
84.7
–
74
–
67.3
–
–
–
–
–
TLP-A145-090-D
xxx
2
x
2000
130.1
–
103.3
–
–
90.2
82
–
–
–
–
–
–
–
–
TLP-A145-100-D
xxx
2
x
3000
–
106.8
–
–
–
84.7
–
74
–
67.3
–
–
–
–
–
TLP-A145-150-D
xxx
2
x
3000
–
113.6
–
–
–
90.2
–
78.8
–
71.6
–
–
–
–
–
TLP-A200-200-D
xxx
2
x
3000
–
125.9
–
–
–
99.9
–
87.3
–
79.3
–
–
–
–
–
TLP-A200-300-D
xxx
2
x
2500
–
140
–
–
–
111.1
–
97.1
–
88.2
–
–
–
–
–
TLP-A200-350-D
xxx
2
x
3000
–
140
–
–
–
111.1
–
97.1
–
88.2
–
–
–
–
–
TLP-A200-450-D
xxx
2
x
3000
–
149.7
–
–
–
118.8
–
103.8
–
94.3
–
–
–
–
–
TLP-A200-550-D
xxx
2
x
3000
–
149.2
–
–
–
118.4
–
103.4
–
94
–
–
–
–
–
TLP-A200-750-D
xxx
2
x
2500
–
159.3
–
–
–
126.4
–
110.4
–
100.3
–
–
–
–
–
TLP-A235-11K-D
xxx
2
x
2000
435
–
345.3
–
–
301.6
274
–
–
–
–
–
–
–
–
TLP-A235-15K-D
xxx
2
x
2000
463.1
–
367.6
–
–
321.1
291.7
–
–
–
–
–
–
–
–
Axial load force applied to the center of the shaft.
Radial load force applied at the midpoint of the shaft extension.