36
Publication CC-QS015A-EN-P - November 2009
Chapter 2
System Validation and Application Tips
20.
Press MORE INFO.
21.
Press RETURN.
22.
Press START RESET for three seconds
and release.
The load is still interrupting the light
curtain. Pressing and releasing START
RESET initiated a Mute Dependent
Override, t(mdo). The system switches
to muted operation. Muting ends as
soon as the load clears the light curtain
or when the configured t(mdo) expires.
23.
Carefully disconnect then reconnect
one of the light curtain cables from the
MSR42 relay at its RJ45 socket.
TIP
When the START RESET button is green, it may be used in place of the Start Reset push button. If
requirements dictate that remote reset must not be used, do not use it. If the operator stationed at
the PanelView terminal’s location cannot see the guarded area well enough to be certain that no
one is in the guarded area, you must not use the START RESET button.
The START RESET button can be disabled by removing three wires from the MicroLogix controller
I/O.
•
Wire 6041
•
Wire 10231
•
Wire 10071