GuardPLC Digital Input/Output Module     

7

Rockwell Automation Publication 1753-IN003C-EN-P - June 2010

Safety-related Digital Inputs

The module has 20 digital inputs (DI1…DI20) whose status is indicated via status indicators.

LS+ is a voltage source that provides 24V DC for a group of four dry contact inputs. There are 
five groups on the module.

If devices require 24V DC to operate and use the same power source as the module, then wire the 
outputs of the device directly to inputs on the module.

L-

L-

L+

L+

1

LS+          

LS+

LS+

LS+

LS+

L-

D1

2 3 4

13 14 15 16 17 18

5

L-

D1

6 7 8

19 20 21 22 23 24

9

L-

D1

10 11 12

25 26 27 28 29 30

13

L-

D1

14 15 16

31 32 33 34 35 36

17

L-

D1

18 19 20

37 38 39 40 41 42

19 20 21 22 23 24

13 14 15 16 23 24

1

L-

L-

DO

2 3 4

(2A)

1 2 3 4 5 6

1 2 3 4 5 6

7

L-

L-

DO

8 9 10

(2A)

7 8 9 10 11 12

7 8 9 10 11 12

25 26 27 28 29 30

31 32 33 34 35 36

37 38 39 40 41 42

24V DC

RUN

24 V DC

PROG

ERROR

FAULT

FORCE

BL 

OSL

GuardPLC Ethernet

10/100 BaseT

1 (—)

2

(—)

1753-IB20OXB8

20 DC Inputs
8 DC Outputs

1

LS+-

L-

D1

2 3 4

13 14 15 16 17 18

13 14 15 16 23 24

L-

L-

L+

L+

24V DC

24V DC

Power 
Supply

COM

+

Connection of Voltage 

Supply to Input Device

L-

L-

L+

L+

1

LS+          

LS+

LS+

LS+

LS+

L-

D1

2 3 4

13 14 15 16 17 18

5

L-

D1

6 7 8

19 20 21 22 23 24

9

L-

D1

10 11 12

25 26 27 28 29 30

13

L-

D1

14 15 16

31 32 33 34 35 36

17

L-

D1

18 19 20

37 38 39 40 41 42

19 20 21 22 23 24

13 14 15 16 23 24

1

L-

L-

DO

2 3 4

(2A)

1

2

3 4

5

6

1

2

3 4

5

6

7

L-

L-

DO

8 9 10

(2A)

7

8

9 10 11 12

7

8

9 10 11 12

25 26 27 28 29 30

31 32 33 34 35 36

37 38 39 40 41 42

24V DC

RUN

24 V DC

PROG

ERROR

FAULT

FORCE

BL 

OSL

GuardPLC Ethernet

10/100 BaseT

1 (—)

2

(—)

1753-IB20OXB8

20 DC Inputs
8 DC Outputs

1

LS+-

L-

D1

2 3 4

13 14 15 16 17 18

13 14 15 16 23 24

L-

L-

L+

L+

24V DC

COM

24V DC

Power 
Supply

COM

+

+

Light Curtain

(or any Safety Input)

Connection of Voltage Supply 

to Input Device

Содержание Allen-Bradley GuardPLC 1753-IB20XOB8

Страница 1: ...8 Topic Page Important User Information 2 About the Module 3 General Safety 3 Install the Module 4 Mount the Module 5 Ground the Module 5 Wire the Module 6 Make Connections for Safety related Communication 12 Reset Push Button 12 Status Indicators 13 Specifications 14 Additional Resources 18 ...

Страница 2: ...particular installation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation Inc with respect to use of information circuits equipment or software described in this manual Reproduction of the contents of this manual in whole or in part without written permission of Rockwell Automati...

Страница 3: ...on of the system and shall be trained in using the system ATTENTION This equipment is sensitive to electrostatic discharge which can cause internal damage and affect normal operation Follow these guidelines when you handle this equipment Touch a grounded object to discharge static potential Wear an approved wrist strap grounding device Do not touch connectors or pins on component boards Do not tou...

Страница 4: ...d disturbances This equipment is supplied as open type equipment It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts The enclosure must have suitable flame retardant properties to prevent or minimize the spread of flame compl...

Страница 5: ...n on proper grounding guidelines refer to the Industrial Automation Wiring and Grounding Guidelines publication 1770 4 1 IMPORTANT For effective cooling mount the module following these guidelines Mount the module horizontally Provide a gap of at least 100 mm 3 94 in above and below the module Select a location where air flows freely or use an additional fan Do not mount the module over a heating ...

Страница 6: ...ons A PELV supply has the same rating and is connected to protected earth The supply voltage is connected via a 4 pin connector that accommodates wire sizes up to 2 5 mm2 14 AWG You need to connect only one wire to L and one wire to L Both L and L terminals are internally connected so you can daisy chain 24V DC power from the module to other devices in the panel by using the remaining terminal IMP...

Страница 7: ... 9 10 11 12 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 24V DC RUN 24 V DC PROG ERROR FAULT FORCE BL OSL GuardPLC Ethernet 10 100 BaseT 1 2 1753 IB20OXB8 20 DC Inputs 8 DC Outputs 1 LS L D1 2 3 4 13 14 15 16 17 18 13 14 15 16 23 24 L L L L 24V DC 24V DC Power Supply COM Connection of Voltage Supply to Input Device L L L L 1 LS LS LS LS LS L D1 2 3 4 13 14 15 16 17 18 5 L D1 6 7 8 19 20 2...

Страница 8: ... connected to these terminals Terminal Number Designation Function 13 LS Sensor supply for inputs 1 4 14 1 Digital input 1 15 2 Digital input 2 16 3 Digital input 3 17 4 Digital input 4 18 L Reference pole L L L L 1 LS LS LS LS LS L D1 2 3 4 13 14 15 16 17 18 5 L D1 6 7 8 19 20 21 22 23 24 9 L D1 10 11 12 25 26 27 28 29 30 13 L D1 14 15 16 31 32 33 34 35 36 17 L D1 18 19 20 37 38 39 40 41 42 19 20...

Страница 9: ...nput 6 22 7 Digital input 7 23 8 Digital input 8 24 L Reference pole 25 LS Sensor supply for inputs 9 12 26 9 Digital input 9 27 10 Digital input 10 28 11 Digital input 11 29 12 Digital input 12 30 L Reference pole 31 LS Sensor supply for inputs 13 16 32 13 Digital input 13 33 14 Digital input 14 34 15 Digital input 15 35 16 Digital input 16 36 L Reference pole 37 LS Sensor supply for inputs 17 20...

Страница 10: ...s that is when one of the E stop off switches is pressed in the example above Safety related Digital Outputs The module has eight digital outputs DO1 DO8 whose status is indicated via status indicators An output is in a safe state when it is de energized If a fault occurs all outputs are turned off Outputs 1 3 and 5 7 can have a load of 0 5 A at an ambient temperature of 60 C 140 F Outputs 4 and 8...

Страница 11: ...t 2 4 3 Digital output 3 5 4 Digital output 4 6 L Reference pole 7 L Reference pole 8 5 Digital output 5 9 6 Digital output 6 10 7 Digital output 7 11 8 Digital output 8 12 L Reference pole TIP Inductive loads can be connected without a protection diode on the load However Rockwell Automation strongly recommends that a protection diode be fitted directly to the load to suppress any interference vo...

Страница 12: ...t via the push button is necessary under the following conditions You forget the password to go online via the programming software You are unable to determine the IP address and SRS of the controller The push button is accessible through a small round hole at the top of the housing approximately 4 5 cm 1 6 2 0 in from the left rim and recessed approximately 9 5 mm 0 375 in To reset press and hold...

Страница 13: ...r due to exceeded cycle time All system outputs will be reset and the controller ceases all hardware and software tests The controller can only be restarted by a command from the programming software Off No errors are detected PROGress On The upload of a new controller configuration is in progress Flashing The upload of a new operating system into the nonvolatile ROM is in progress Off No upload o...

Страница 14: ...per wire rated at 75 C 167 F or greater with 1 2 mm 3 64 in insulation max Ethernet RJ45 connector according to IEC 60603 7 2 or 4 pair Category 5e minimum cable according to TIA 568 B 1 or Category 5 cable according to ISO IEC 24702 Wire type Shielded on Ethernet Terminal Block Torque 0 51 N m 4 5 lb in Fuse external 24V DC power 10 A time lag Pilot Duty Rating Not rated Response time 10 ms Batte...

Страница 15: ...channels 1 3 and 5 7 4 A for 10 ms 1Hz channels 4 and 8 Current load min 2 mA per channel Internal voltage drop 2V max 2 A Leakage current with 0 signal 1 mA max 2V Total output current 7 A max with exceeding shut down of all outputs with cyclic reconnecting Response overload Shut down of the concerned output with cyclic reconnecting 1 Use this Conductor Category information for planning conductor...

Страница 16: ...EC 60068 2 27 Test Ea unpackaged shock 15 g Relative humidity IEC 60068 2 30 Test Db unpackaged damp heat 10 95 noncondensing Emissions CISPR 11 Group 1 Class A ESD Immunity IEC 61000 4 2 6 kV contact discharges 8 kV air discharges Radiated RF Immunity IEC 61000 4 3 10V m with 1kHz sine wave 80 AM from 80 MHz 2000 MHz 1 V m with 1 kHz sine wave 80 AM from 2000 2700 MHz EFT B Immunity IEC 61000 4 4...

Страница 17: ...t certified for US and Canada See UL File E65584 CE European Union 2004 108 EC EMC Directive compliant with EN 61326 1 Meas Control Lab Industrial Requirements EN 61000 6 2 Industrial Immunity EN 61000 6 4 Industrial Emissions EN 61131 2 Programmable Controllers Clause 8 Zone A B C Tick Australian Radiocommunications Act compliant with AS NZS CISPR 11 Industrial Emissions Functional Safety Certifi...

Страница 18: ...LC Controller Systems Safety Reference Manual publication 1753 RM002 Detailed information regarding the safety certification of the GuardPLC System GuardPLC Controller Systems User Manual publication 1753 UM001 Detailed information on installing wiring configuring operating maintaining and troubleshooting GuardPLC systems Using RSLogix Guard PLUS Software with GuardPLC Controllers Programming Manu...

Страница 19: ...GuardPLC Digital Input Output Module 19 Rockwell Automation Publication 1753 IN003C EN P June 2010 ...

Страница 20: ...is manual You can also contact a special Customer Support number for initial help in getting your product up and running New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures Documentation Feedback...

Отзывы: