38
Rockwell Automation Publication IOLINK-UM001A-EN-P - August 2017
Appendix B
Message Structure and Configuration Examples
Figure 1 - Message Configuration
The following table identifies the data that are required to complete the
Message Configuration dialog box to Read the “Vendor Name” from the 836P
pressure switch:
Item Description
Value
1
Message Type
- The message type is CIP™ Generic.
CIP Generic
2
Service Type
-
The service type is Custom.
Custom
3
Service Code
- Established from Service Code Table.
4D
4
Class
- The class is 3a3.
3a3
5
Instance
- Established from
. Identifies the Index for the
Parameter being read.
16
6
Attribute
- The Attribute value is 0.
0
7
Source Element
- Contains the name of the tag of the channel
number to be read.
Write_Assembly[0]
8
Source Length
- This box contains the number of bytes of service data
to be sent or received in message. Defined in Data Structure Tables.
1 byte
9
Destination Element
- First element of the destination Array.
Read_Assembly[0]
Содержание Allen-Bradley 836P Series
Страница 1: ...IO Link for Solid state Pressure Switches Catalog Number 836P Dx User Manual OriginalInstructions...
Страница 22: ...22 Rockwell Automation Publication IOLINK UM001A EN P August 2017 Chapter 3 Create a Project Notes...
Страница 30: ...30 Rockwell Automation Publication IOLINK UM001A EN P August 2017 Chapter 5 Register the 836P IODD Notes...
Страница 45: ......