6
Rockwell Automation Publication 6300V-IN004A-EN-P - November 2022
Remote Video Link Receiver for 6300B Box PCs and 6300T Box Thin Clients Installation Instructions
10. Align and install the other connector clamp half to complete the assembly (F in
11.
Reconnect the DC terminal block with the connector assembly to your RVL receiver (G in
12.
Torque the DC terminal block flange screws to the values in
13.
Turn on the main power switch or breaker.
14.
Tighten the screws on top of the DC terminal block to secure the DC power wires to the torque value in
Install the Ground Wire
1.
Be sure that the main power switch or breaker is still turned off.
2.
Remove the supplied nut, eyelet terminal, and washers from the ground screw on the side of your RVL receiver. See
for the ground screw location.
3.
Attach a 2.50 mm
2
(14 AWG) or larger external wire to the eyelet terminal.
4.
Strip 5.00 mm (0.20 in.) from the covering at the end of the grounding wire.
5.
Insert the stripped end of the grounding wire into the open end of the eyelet terminal, and crimp it securely to the wire.
6.
Install the ground wire and washers to the ground screw in the following sequence:
7.
Reinstall the ground screw to the chassis of your RVL transmitter.
When installed correctly, both tabs of the clamp half lock into place.
SHOCK HAZARD:
The chassis of your RVL receiver must be connected to ground via the ground screw.
Use a grounding wire with an insulation color that is approved by your local inspection authority.
Note No.
Description
1
Toothed washer
2
Eyelet terminal
3
Washer
4
Lock washer
5
Ground screw
We recommend that the computer circuit be supplied with its own disconnect.
Use an uninterruptible power supply (UPS) to help protect against unexpected power failure or power surges.
1
4
2
3
5