Rockwell Automation Publication 6181X-IN002D-EN-P - February 2020
29
Industrial Computers for Hazardous Locations
Power Specifications
Environmental Specifications
Attribute
6181X-12A2SW71DC,
6181X-00N2SW71DC,
6181X-12A2SWX1DC,
6181X-00N2SWX1DC
6181X-12P2SWX1DC
Input voltage, DC
18…32V DC
Power consumption, max
• Non-display models
• Display models
18…32V DC (SELV), 2.22…1.25 A, 40 W
18…32V DC (SELV), 2.78…1.56 A, 50 W
18…32V DC (SELV), 3.32…1.87 A, 60 W
Heat dissipation
(1)
• Non-display models
Display models
(1)
Add-in cards and peripherals are included in the heat dissipation value.
40 W (136 BTU/h)
50 W (171 BTU/h)
60 W (205 BTU/h)
Peripheral loading
• PCIe card, max
• USB ports, max per port
4 W
900 mA, 10 W max for all ports (2 A)
4 W
900 mA
Attribute
6181X-12A2SW71DC,
6181X-00N2SW71DC,
6181X-12A2SWX1DC,
6181X-00N2SWX1DC
6181X-12P2SWX1DC
Temperature, operating
• Non-display models
• Display models
(1)
(1)
See
Installation Guidelines on page 8
for more information about temperature guidelines.
-20…+70 °C (-4…+158 °F)
-20…+55 °C (-4…+131 °F), display side; -20…+70 °C (-4…+158 °F), back side
Temperature, nonoperating
-30…+80 °C (-22…+176 °F)
Relative humidity
10…90% without condensation
Altitude, operating
2000 m (6561 ft)
Altitude, nonoperating
12,000 m (40,000 ft)
Shock, operating
(2)
(2)
Applies to panel-mounted integrated display computers and wall-mounted non-display computers.
15 g (1/2 sine, 11 ms)
Shock, nonoperating
(2)
30 g (1/2 sine, 11 ms)
Vibration, operating
(2)
0.012 in p-p (10…57 Hz); 2 g peak (57…640 Hz)
Enclosure ratings
Display models
Rated for UL Type1. 4, 4X, 12, 13 and classified by UL in accordance with IEC 60529,
IP66 when properly mounted on a flat surface of an equivalent-type enclosure.