Rockwell Automation Publication 2198-RM004C-EN-P - March 2022
69
Chapter 6 Application Conversion
Figure 43 - Gear Ratio Window in KNX5100C Software
You can configure the operation mode (PT Mode) of the drive and select the
Command Source for the Master input in KNX5100C software.
The PTO inputs of the Kinetix 300 or the Kinetix 5100 servo drives can be
differential or single ended. Differential inputs are preferred.
The Kinetix 5100 drive also provides the ability to filter pulse input and to
reject high-frequency noise. Using a filter width that is four times smaller than
the actual pulse width is recommended. The supported filter widths are shown
in
Table 55 - PTO Input Compatibility Between Kinetix 300 drives and Kinetix 5100 drives
Attribute
Kinetix 300 drive
Kinetix 5100
Recommended voltage 5 … 24V DC
5V DC for differential signal, 21.6…26.4V DC for single-
ended signal
Input frequency (max)
2 MHz (differential signal)
4 MHz (differential signal)
200 kHz (single-ended signal)
Pulse width
500 ns
125 ns (differential signal)
2.5 us (single-ended signal)
Table 56 - Pulse Input Filter Supported on Kinetix 5100 Drives
Filter Width
Filter Width
Filter Width
Filter Width
Filter Width
Filter Width
No filter
0.6 μs
1.1 μs
2 μs
7 μs
12 μs
0.2 μs
0.7 μs
1.2 μs
3 μs
8 μs
13 μs
0.3 μs
0.8 μs
1.3 μs
4 μs
9 μs
14 μs
0.4 μs
0.9 μs
1.4 μ
5 μs
10 μs
15 μs
0.5 μs
1 μs
1.5 μs
6 μs
11 μs
Содержание Allen-Bradley 2198-E1004-ERS
Страница 10: ...10 Rockwell Automation Publication 2198 RM004C EN P March 2022 Chapter 1 Migration Options Notes ...
Страница 36: ...36 Rockwell Automation Publication 2198 RM004C EN P March 2022 Chapter 2 Replacement Considerations Notes ...
Страница 56: ...56 Rockwell Automation Publication 2198 RM004C EN P March 2022 Chapter 4 Dimensions Cables and Wiring Notes ...