Channel 1
Module Properties Dialog Box 16
Serial Character Framing
0…8
0 = 7N2, 1 = 7E1, 2 = 7O1, 3 = 8N1, 4 = 8N2, 5 = 8E1,
6 = 8O1, 7 = 7E2, 8 = 7O2
CH1BaudRate
17
Serial Port Speed
0…7
0 = 9600, 1 = 1200, 2 = 2400, 3 = 4800, 4 = 19200,
5 = 38400, 6 = 57.6k, 7 = 115.2k (half-duplex only)
Serial Port Receive Data
Module Properties Dialog Box 18
Max Number of Receive Characters
0…200
In Simultaneous mode, the total number of channel 0 characters plus
channel 1 characters cannot exceed 200.
Ch1RxStartMode
19
Receive Record Start Mode
0…2
0 = ignore, 1 = exclude, 2 = include start delimiter
Ch1RxStartDelimiter
20
Receive Start Delimiter
0…127/255
0…0x7f (0…127) for 7-bit data
0…0xff (0…255) for 8-bit data
Ch1RxEndMode
21
Receive Record End Mode
0…2
0 = ignore, 1 = exclude, 2 = include end delimiter
Ch1RxEndDelimiter
22
Receive End Delimiter
0…127/255
0…0x7f (0…127) for 7-bit data
0…0xff (0…255) for 8-bit data
Module Production Data
Ch1RxPadChar
23
Pad Character
0…127/255
0…0x7f (0…127) for 7-bit data
0…0xff (0…255) for 8-bit data
Ch1RxByteSwapMode
24
Receive Swap Mode
0…2
0 = disabled, 1 = 16-bit, 2 = 32-bit
Ch1RxByteHandshakeMode
25
Master Handshake Mode
0…1
0 = master/slave handshake, 1 = produce immediate
CH1RxMessageTimeout
26
Message Time Out
0…65535
0 = none, 1 to 65535 ms
Serial Port Transmit Data
Module Properties Dialog Box 27
Max Number of Transmit Characters
0…200
In Simultaneous mode, the total number of channel 0 characters plus
channel 1 characters cannot exceed 200.
Ch1TxEndMode
28
Transmit Record End Mode
0…2
0 = ignore, 1 = exclude, 2 = include end delimiter
Ch1TxEndDelimiter
29
Transmit End Delimiter
0…127/255
0…0x7f (0…127) for 7-bit data
0…0xff (0…255) for 8-bit data
Ch1TxByteSwapMode
30
Transmit Swap Mode
0…2
0 = disabled, 1 = 16-bit, 2 = 32-bit
(1) To enter values 128…255, use this conversion formula: Desired Decimal Value - 256 = Entered Decimal Value. For example, for an ASCII character value of 128, 128 - 256 = -128.
Table 9 - Configuration File Tag Names (Continued)
Tag Definition
Wo
rd
Description
Values
Valid Data Values
Содержание Allen-Bradley 1769-ASCII
Страница 1: ...Compact I O ASCII Module Catalog Numbers 1769 ASCII User Manual ...
Страница 4: ...4 Rockwell Automation Publication 1769 UM012B EN P January 2014 Summary of Changes Notes ...
Страница 20: ...20 Rockwell Automation Publication 1769 UM012B EN P January 2014 Chapter 1 Compact I O ASCII Module Notes ...
Страница 65: ...Rockwell Automation Publication 1769 UM012B EN P January 2014 65 Configure the 1769 ASCII Module Chapter 2 ...
Страница 67: ...Rockwell Automation Publication 1769 UM012B EN P January 2014 67 Configure the 1769 ASCII Module Chapter 2 ...
Страница 86: ...86 Rockwell Automation Publication 1769 UM012B EN P January 2014 Chapter 3 I O Memory Mapping Notes ...
Страница 96: ...96 Rockwell Automation Publication 1769 UM012B EN P January 2014 Appendix B Status Indicators Notes ...
Страница 101: ...Rockwell Automation Publication 1769 UM012B EN P January 2014 101 Error Codes Appendix C ...
Страница 112: ...112 Rockwell Automation Publication 1769 UM012B EN P January 2014 Appendix E Using Electronic Keying Notes ...
Страница 114: ...114 Rockwell Automation Publication 1769 UM012B EN P January 2014 Appendix F History of Changes Notes ...
Страница 117: ......