Rockwell Automation Publication 450L-UM001F-EN-P - March 2022
137
Chapter 9 Connected Components Workbench Software
3. Initially, a red message box “Mandatory GPIO configuration is not
complete for download” appears. After making the proper mandatory
selections, the message turns green.
Figure 122 - GPIO Overview
lists the I/O from the example schematic in
.
There are five inputs on the cascading plug-in and one output on the
connection plug-in.
shows the settings. Click the selection expander for
Cascading plug-in pin five. The four muting sensors appear as mandatory
inputs. Check Muting Sensor 1, as this sensor is connected to pin 5.
Table 62 - Muting I/O
Plug-in
I/O
Function
Pin
Cascading
Input
Muting sensor 1
5
Muting sensor 2
6
Muting sensor 3
1
Muting sensor 4
4
Output
Muting lamp
8
Connection
Input
Muting override
8
Output
Mute timing error
1
Mute sequence error
4
Содержание Allen-Bradley 140M
Страница 8: ...8 Rockwell Automation Publication 450L UM001F EN P March 2022 Table of Contents Notes ...
Страница 20: ...20 Rockwell Automation Publication 450L UM001F EN P March 2022 Chapter 2 Safety Concepts Notes ...
Страница 108: ...108 Rockwell Automation Publication 450L UM001F EN P March 2022 Chapter 7 Status Indicators and Troubleshooting Notes ...
Страница 114: ...114 Rockwell Automation Publication 450L UM001F EN P March 2022 Chapter 8 Safety Instructions Notes ...
Страница 184: ...184 Rockwell Automation Publication 450L UM001F EN P March 2022 Appendix B Typical Installations Notes ...
Страница 190: ...190 Rockwell Automation Publication 450L UM001F EN P March 2022 Index ...
Страница 191: ...Rockwell Automation Publication 450L UM001F EN P March 2022 191 GuardShield Safety Light Curtain User Manual ...