138
Rockwell Automation Publication 450L-UM001F-EN-P - March 2022
Chapter 9 Connected Components Workbench Software
Figure 123 - Select I/O for Pin 5
shows the sensor settings to adjust the sensor
logic and filter times.
The Logic function for muting sensor is fixed at LOW Active. When an object
passes in front of the sensor, the sensor output turns OFF.
Adjust the filter times to help prevent inadvertent changes from the sensor
output from disrupting the muting process. The filter times can be adjusted
from 0…255 ms.
Click OK after adjustments are made.
Figure 124 - Muting Sensor Settings
shows the final GPIO settings to meet the example
schematic. The mandatory GPIO message box is green.