Publication 1734-UM015A-EN-E - November 2009
28
Install ArmorPOINT I/O DeviceLogix Modules
Mounting illustration for the ArmorPOINT adapter with I/O bases
Install the mounting as follows:
1.
Lay out the required points as shown above in the drilling dimension
drawing.
2.
Drill the necessary holes for M4 (#8) machine or self-tapping screws.
3.
Mount the base using M4 (#8) screws.
4.
Ground the system using the ground lug connection.
The ground lug connection is also a mounting hole.
Adapter
102 mm
4.02 in
46 mm
1.81 in
47.2 mm
1.9 in
50 mm
2.0 in
22 mm
0.87 in
22 mm
0.87 in
50 mm
2.0 in
50 mm
2.0 in
Adapter
102 mm
4.02 in
46 mm
1.81 in
47.2 mm
1.9 in
50 mm
2.0 in
22 mm
0.87 in
22 mm
0.87 in
50 mm
2.0 in
50 mm
2.0 in
43769
Ground lug connection
Latching mechanism
43675